• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. KREULOCK SCREW, TI, 3.5X26; BONE FIXATION PLATE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. KREULOCK SCREW, TI, 3.5X26; BONE FIXATION PLATE Back to Search Results
Model Number KREULOCK SCREW, TI, 3.5X26
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code Failure of Implant (1924)
Date of Event 05/03/2024
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Investigation is in process.A follow-up report will be provided upon availability of additional information.
 
Event or Problem Description
On 8/12/2024, it was reported by a patient via email that a cancellous compression screw, being used with a trocar tip to stabilize a lisfranc injury, broke off in the foot.The broken fragments were not removed.On 8/19/2024, the patient reported that the procedure took place on (b)(6) 2024 in which an ar-8935cl-26 kreulock compression screw, an ar-8935-22 non-locking low profile screw, an ar-8935cl-32 kreulock compression screw, and an ar-8951mr medium right lisfranc plate was implanted.Additionally, another plate and 5 screws with unknown part numbers were also implanted.During the procedure, one of the screws broke about the fifth thread down.At this time, it is unknown which screw broke.The surgeon decided to leave the broken fragment in the patient, as removing it would cause more harm.Once the patient was healed, on (b)(6) 2024, a second procedure was performed to remove both plates and eight screws, except the body of the previously broken screw.The part number for the trocar tip remains unknown.
 
Additional Manufacturer Narrative
Additional information: e4, g3, h3, h6, h10.The complaint device was not received for evaluation.Based on the provided information, which may include the device (if available and returned), pictures, videos, event descriptions, and any additional field data, arthrex concluded the most likely cause of the reported failure is user error.This includes improper bone preparation, misaligned insertion, and/or prying or levering the device during insertion, which resulted in the device breaking.The complaint allegation was confirmed based on the customer's attached picture, where the blue screw is shown missing part of its body.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
KREULOCK SCREW, TI, 3.5X26
Common Device Name
BONE FIXATION PLATE
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key20146330
Report Number1220246-2024-07380
Device Sequence Number19886113
Product Code HRS
UDI-Device Identifier00888867323223
UDI-Public00888867323223
Combination Product (Y/N)N
Initial Reporter StateCO
Initial Reporter CountryUS
PMA/510(K) Number
K201132
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2024
Device Explanted Year2024
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 07/03/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberKREULOCK SCREW, TI, 3.5X26
Device Catalogue NumberAR-8935CL-26
Device Lot Number15078868
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/12/2024
Supplement Date Received by Manufacturer06/10/2025
Initial Report FDA Received Date09/05/2024
Supplement Report FDA Received Date07/03/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/10/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age65 YR
Patient SexMale
-
-