• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TERUMO BCT IMUGARD; IMUGARD WB PLT PLATELET POOLING SET

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TERUMO BCT IMUGARD; IMUGARD WB PLT PLATELET POOLING SET Back to Search Results
Catalog Number 5419501
Medical Device Problem Codes Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/20/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation is in process, a follow-up will be provided.
 
Event or Problem Description
The customer reported elevated white blood cell (wbc) content in a pooled blood product.Donor unit id # (b)(6) there was not a transfusion recipient or patient involved at the time of the unit processing, therefore no patient information is reasonably known at the time of the event.The collection set is not available for return because it was discarded by the customer.
 
Event or Problem Description
The customer reported elevated white blood cell (wbc) content in a pooled blood product.Donor unit id # (b)(6) there was not a transfusion recipient or patient involved at the time of the unit processing, therefore no patient information is reasonably known at the time of the event.The collection set is not available for return because it was discarded by the customer.
 
Additional Manufacturer Narrative
This report is being filed to provide additional information in d.4, e.1, h.6, and h.11 and a correction in b.3.Investigation: an investigation was conducted for the imugard platelet pooling set leukoreduction failure.The terumo bct field performance team visited the customer sites to observe the platelet manufacturing process, and more specifically the platelet pooling process using the imugard pooling sets.The focus of this visit was to observe the processes to identify any possible causes or contributing factors to the leukoreduction failures observed beginning in (b)(6) 2024 and peaking in (b)(6) 2024.Many of the events occurred in may, which was shortly before both preventive maintenance and calibration verification were due on the sysmex instrument used to measure wbcs for those products.A review of the device history record (dhr) for this lot showed no irregularities during manufacturing that were relevant to this issue.A disposable complaint history search was performed for this lot and found no reports for similar issues on this lot.Root cause: a root cause assessment was performed for this complaint.Based on the available information a definitive root cause could not be determined but it is likely due to one or a combination of the possible causes listed below: cell counter calibration and performance during the month of may.Minor differences in product handling and sampling processes compared to more typical processes.Variation in manual expression steps of the platelet production process.Possible differences in processes between the platelet manufacturing sites.A defective supplier component (filter).
 
Additional Manufacturer Narrative
This report is being filed to provide additional information in g.3.Investigation: an investigation was conducted for the imugard platelet pooling set leukoreduction failure.The terumo bct field performance team visited the customer sites to observe the platelet manufacturing process, and more specifically the platelet pooling process using the imugard pooling sets.The focus of this visit was to observe the processes to identify any possible causes or contributing factors to the leukoreduction failures observed beginning in (b)(6) of 2024 and peaking in (b)(6) of 2024.Many of the events occurred in (b)(6), which was shortly before both preventive maintenance and calibration verification were due on the sysmex instrument used to measure wbcs for those products.A review of the device history record (dhr) for this lot showed no irregularities during manufacturing that were relevant to this issue.A disposable complaint history search was performed for this lot and found no reports for similar issues on this lot.Root cause: a root cause assessment was performed for this complaint.Based on the available information a definitive root cause could not be determined but it is likely due to one or a combination of the possible causes listed below: cell counter calibration and performance during the month of may.Minor differences in product handling and sampling processes compared to more typical processes.Variation in manual expression steps of the platelet production process.Possible differences in processes between the platelet manufacturing sites.A defective supplier component (filter).
 
Event or Problem Description
The customer reported elevated white blood cell (wbc) content in a pooled blood product.Donor unit id # (b)(6) there was not a transfusion recipient or patient involved at the time of the unit processing; therefore, no patient information is reasonably known at the time of the event.The collection set is not available for return because it was discarded by the customer.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IMUGARD
Common Device Name
IMUGARD WB PLT PLATELET POOLING SET
Manufacturer (Section D)
TERUMO BCT
lakewood CO 80215
Manufacturer (Section G)
TERUMO BCT
10810 w. collins ave
lakewood CO 80215
Manufacturer Contact
scot hilden
10810 w. collins ave
lakewood, CO 80215
MDR Report Key20175832
Report Number1722028-2024-00384
Device Sequence Number8298299
Product Code KSR
UDI-Device Identifier05020583419506
UDI-Public05020583419506
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
BK230838
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 09/09/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/31/2025
Device Catalogue Number5419501
Device Lot Number2305101151
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/16/2024
Supplement Date Received by Manufacturer08/16/2024
01/23/2025
Initial Report FDA Received Date09/09/2024
Supplement Report FDA Received Date01/23/2025
01/23/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured05/02/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-