|
EXACTECH, INC. LOGIC TIBIA PS MOD INSRT SZ 5 9MM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
02-012-35-5009 |
| Medical Device Problem Codes |
Unstable (1667); Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Emotional Changes (1831); Inflammation (1932); Pain (1994); Scar Tissue (2060); Ambulation or Postural Difficulties (2544); Joint Laxity (4526); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581); Joint effusion (4849)
|
| Date of Event |
10/17/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Legal case - usa - mdl (3044).It was reported via legal documentation that approximately 88 months after a left total knee replacement procedure, the patient has experienced prosthesis wear, pain, swelling, effusion, inflammation, instability, antalgic gait, emotional distress.No further issues or complications were reported.No additional information is available.
|
| |
|
Additional Manufacturer Narrative
|
|
Concomitants: 2631603, 02-010-01-0250 - logic femoral ps cem left sz 5.3843240, 02-012-45-5040 - lgc tibial fit tray cem sz 5f / 4t.3984870, 200-02-38 - three peg patella 38mm.4023063, 204-34-02 - fluted stem extension 25l x 14 mm.4015501, 204-70-00 - tibial stem ext.Screw.The product associated with the reported event is within the scope of recall z-0021-2022; however, there is insufficient information to evaluate whether the subject issue of the recall was a cause or contributor to the reported event.The device was not returned for evaluation and no medical or other records containing treatment information or patient information have been received; therefore, the reported event cannot be confirmed, nor can the circumstances or potential causes or contributors to the alleged event be evaluated.Should additional, material information become available that permits more analysis or conclusions, a supplemental report will be filed accordingly.
|
| |
|
Additional Manufacturer Narrative
|
|
The reason for the revision reported cannot be confirmed from the information provided but may be the result of prosthesis wear and instability or due to inclusion of the polyethylene in the packaging recall.Potential contributions of user and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and images, radiographs, and relevant clinical information were not provided.H6: corrected health effect, medical device, and investigation clinical codes.
|
| |
|
Search Alerts/Recalls
|
|
|