Model Number 9010
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Aneurysm (1708); Stenosis (2263); Pseudoaneurysm (2605); Thrombosis/Thrombus (4440); Restenosis (4576)
Date of Event 06/27/2024
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported through the results of a clinical trial that sometime post an index procedure completion using a drug-coated balloon catheter in the cephalic vein at outflow near cannulation zone via the left upper arm, the subject had adverse event of pseudoaneurysm on pre-dilation and aneurysm on cephalic vein.It was further reported that one month and eleven days after index procedure, the subject had serious adverse event due to cephalic vein restenosis and access circuit thrombosis which required an arteriovenous access circuit reintervention.Furthermore, one month and nineteen days after index procedure, standard percutaneous transluminal angioplasty procedure was performed to treat cephalic vein restenosis and access circuit thrombosis.Treatment reintervention was successful, new access was not created, and the outcome of the serious adverse event was resolved.Reportedly, there have been no documented device deficiencies reported for this subject to date.The current status of the patient is unknown.
 
Additional Manufacturer Narrative
H10: as the lot number for the device was provided, a review of the device history records will be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.H10: d4 (expiry date: 05/2025) h11: section a through f ¿ the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Additional Manufacturer Narrative
H10: manufacturing review: the device history records have been reviewed and this lot met all release criteria.There was nothing found to indicate there was a manufacturing related cause for this event.Investigation summary: the physical device was not returned for evaluation.No photos were provided for review.Therefore, the investigation is inconclusive for the reported failure as no objective evidence was provided for review.Based upon the available information, the definitive root cause is unknown.Labeling review: as the reported event did not allege a labeling or use related issue, a labeling review is not required.H11: section a through f ¿ the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Event or Problem Description
It was reported through the results of a clinical trial that sometime post an index procedure completion using a drug-coated balloon catheter in the cephalic vein at outflow near cannulation zone via the left upper arm, the subject had adverse event of pseudoaneurysm on pre-dilation and aneurysm on cephalic vein.It was further reported that one month and eleven days after index procedure, the subject had serious adverse event due to cephalic vein restenosis and access circuit thrombosis which required an arteriovenous access circuit reintervention.Furthermore, one month and nineteen days after index procedure, standard percutaneous transluminal angioplasty procedure was performed to treat cephalic vein restenosis and access circuit thrombosis.Treatment reintervention was successful, new access was not created, and the outcome of the serious adverse event was resolved.Reportedly, there have been no documented device deficiencies reported for this subject to date.The current status of the patient is unknown.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LUTONIX 035 DRUG COATED PTA DILATATION CATHETER
Common Device Name
DRUG COATED BALLOON PTA CATHETER
Manufacturer (Section D)
LUTONIX, INC
9409 science center dr
new hope MN 55428
Manufacturer (Section G)
C.R. BARD, INC. (GFO)
289 bay road
queensbury 12804
Manufacturer Contact
brett curtice
800 w. rio salado pkwy
tempe, AZ 85281
4803032689
MDR Report Key20179463
Report Number3006513822-2024-00059
Device Sequence Number8364233
Product Code PRC
UDI-Device Identifier00801741135422
UDI-Public(01)00801741135422(11)220701(17)250523(10)GFGR0980
Combination Product (Y/N)Y
Initial Reporter CountryCA
PMA/510(K) Number
P170003
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Study
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 10/22/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/23/2025
Device Model Number9010
Device Catalogue NumberLX3575740V
Device Lot NumberGFGR0980
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/15/2024
Supplement Date Received by Manufacturer10/22/2024
Initial Report FDA Received Date09/10/2024
Supplement Report FDA Received Date11/11/2024
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured07/01/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age67 YR
Patient SexMale
Patient Weight72 KG
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-