• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BD CARIBE LTD. BD MICROTAINER® K2E TUBES; BLOOD SPECIMEN COLLECTION DEVICE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BD CARIBE LTD. BD MICROTAINER® K2E TUBES; BLOOD SPECIMEN COLLECTION DEVICE Back to Search Results
Catalog Number 365975
Medical Device Problem Code Coagulation in Device or Device Ingredient (1096)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/07/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A device evaluation and/or device history review is anticipated but is not complete.Upon completion, a supplemental report will be filed.
 
Event or Problem Description
It was reported while analyzing blood samples collected in bd microtainer® k2e tubes, the blood samples coagulated.This occurred ten (10) times.The blood samples were recollected.There was no report of adverse impact to patients or users.
 
Additional Manufacturer Narrative
The following fields were updated due to additional information: d9: device available for evaluation: yes.H.3 device eval by manufacturer? yes.D9: returned to manufacturer on: 09-sep-2024.Investigation summary: material #: 365975.Lot/batch #: 4044896.Bd received 50 samples for investigation.The samples were evaluated by visual examination for presence of additive and 15 samples underwent titration testing for quantity of additive and the indicated failure mode for clotting with the incident lot was not observed.Additionally, 50 retention samples from bd inventory were evaluated by visual examination for presence of additive and 15 retention samples underwent titration testing for quantity of additive and no issues were observed relating to clotting as all samples met specifications.Complaints for sample quality are under statistical control for the month of august 2024.At this time, further testing is not indicated.Based on a review of the device history record for the incident lot, all product specifications and requirements for lot release were met.There were no related quality issues during manufacturing of the product.This complaint is unable to be confirmed for the indicated failure mode clotting.Bd was not able to identify a root cause for the indicated failure mode.Complaints received for this device and reported condition will continue to be tracked and trended.Our business team regularly reviews the collected data for identification of emerging trends.Bd quality will continue to monitor sample quality complaints.
 
Event or Problem Description
It was reported while analyzing blood samples collected in bd microtainer® k2e tubes, the blood samples coagulated.This occurred ten (10) times.The blood samples were recollected.There was no report of adverse impact to patients or users.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD MICROTAINER® K2E TUBES
Common Device Name
BLOOD SPECIMEN COLLECTION DEVICE
Manufacturer (Section D)
BD CARIBE LTD.
road 31
k.m. 24.3
juncos PR
Manufacturer (Section G)
BD CARIBE LTD.
road 31
k.m. 24.3
juncos PR
Manufacturer Contact
jo doyka
7 loveton circle
sparks, MD 21152
4103164000
MDR Report Key20180396
Report Number2618282-2024-00121
Device Sequence Number15634049
Product Code JKA
UDI-Device Identifier30382903659754
UDI-Public(01)30382903659754
Combination Product (Y/N)N
Initial Reporter CountryFI
PMA/510(K) Number
K940905
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Company Representative
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 09/13/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/31/2025
Device Catalogue Number365975
Device Lot Number4044896
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/12/2024
Supplement Date Received by Manufacturer09/13/2024
Initial Report FDA Received Date09/10/2024
Supplement Report FDA Received Date09/25/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured02/13/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-