Model Number ESBF2314C103E
Medical Device Problem Codes Leak/Splash (1354); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Pain (1994); Insufficient Information (4580)
Date of Event 08/21/2024
Type of Reportable Event Serious Injury
Event or Problem Description
An endurant iis stent graft system was implanted during the endovascular treatment of an aaa.It was reported approximately 17 months post the index procedure the patient presented emergently with abdominal pain and a type ia endoleak was identified.The patient was taken to the or and a non-mdt stent was implanted however the endoleak remained.It was noted by the physician that the aortic neck was measuring 12-13mm in diameter and 10mm in length and so the endurant stent graft was constrained and the proximal sealing stent could not fully open as the graft was oversized in relation to the patient¿s anatomy.The proximal endoleak remained after the non mdt stent was implanted.The physician did not feel a good endovascular option existed given how small the aorta was at the renal level and an open repair was performed where the endograft was explanted, with the exception of the suprarenal stent and the most proximal aspect of the graft where the endoanchors were in place.Per the physician the cause of the endoleak was due to oversizing.No additional clinical sequalae were provided and the patient is fine.
 
Additional Manufacturer Narrative
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ENDURANT IIS BIFURCATED STENT GRAFT
Common Device Name
SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TR
Manufacturer (Section D)
MEDTRONIC IRELAND
parkmore business park west
galway
EI 
Manufacturer (Section G)
MEDTRONIC IRELAND
parkmore business park west
galway
EI  
Manufacturer Contact
alison sweeney
parkmore business park west
galway 
EI  
091708096
MDR Report Key20198241
Report Number9612164-2024-04155
Device Sequence Number18028902
Product Code MIH
UDI-Device Identifier00643169439993
UDI-Public00643169439993
Combination Product (Y/N)N
Initial Reporter StatePA
Initial Reporter CountryUS
PMA/510(K) Number
P100021
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Device Explanted Year2024
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/12/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/01/2025
Device Model NumberESBF2314C103E
Device Catalogue NumberESBF2314C103E
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/21/2024
Initial Report FDA Received Date09/12/2024
Date Device Manufactured02/02/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age74 YR