Additional information: g3, h3, h6.Complaint allegation is not confirmed.Based on the information provided which may include the device (if available and returned), pictures, videos, event description, and any additional information from the field, arthrex was able to conclude a most likely cause.Patient sensitivity to device materials must be considered prior to implantation.Per dfu-0087-eo c contraindications 2.Blood supply limitations and previous infections, which may retard healing.3.Foreign body sensitivity.Where material sensitivity is suspected, appropriate tests should be made and sensitivity ruled out prior to implantation.5.Any active infection or blood supply limitations.J.Material specifications suture (if supplied): see package label for size and type of suture provided with device.The fiberwire, fiberwire cl, tigerwire®, tigerwire cl, fibertape, and tigertape¿ sutures are made of ultra high molecular weight polyethylene (uhmwpe) and polyester.The fiberwire and tigerwire sutures include fiberstick¿, tigerstick®, fiberchain®, fiberlink¿, tigerlink¿, tigertail®, fiberloop® and tigerloop¿ sutures.The fiberlink, tigerlink, fiberloop and tigerloop sutures may also be braided from suturetape sutures.Additional materials may include silicone elastomer coating (except suture with the suffix -tape), cyanoacrylate, and may include nylon.Suturetape is made from ultra high molecular weight polyethylene (uhmwpe) and polyester.Additional materials may include nylon and/or cyanoacrylate.The #2 suture, and #5 suture are a polyblend made from ultra high molecular weight polyethylene (uhmwpe) and polyester.Additional materials may include nylon and/or cyanoacrylate.The sutures supplied meet or exceed u.S.And european pharmacopeia standards for non-absorbable surgical sutures (except for diameter requirements).The suture dyes may include: d&c blue no.6, d&c green no.6, logwood black, fd&c blue no.2, d&c black no 4 and chromium cobalt aluminum oxide.Suture strands that are dyed with logwood black are made of nylon.Other non-absorbable suture is made from polyester, polytetrafluoroethylene (ptfe) coating, and cyanoacrylate.K.Storage conditions bioabsorbable devices must be stored in the original unopened packaging in a dry place at maxi k.Storage conditions bioabsorbable devices must be stored in the original unopened packaging in a dry place at maximum 32° c / 90° f and should not be used after the expiration date.Non-bioabsorbable devices must be stored in the original unopened packaging, away from moisture and should not be used after the expiration date.The most likely cause of the reported failure is a patient-specific event.The surgeon performed the revision surgery using the same part that caused the patient's reaction to the first surgery.Also, per our records, the device used to perform the revision surgery on (b)(6) 2024, expired on september 30, 2023.
|