Model Number ECLIPSE CAGE SCREW L, 40MM
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code Failure of Implant (1924)
Date of Event 09/01/2016
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a revision surgery was necessary on (b)(6) 2016 after the initial implantation on (b)(6) 2013 due to a broke out glenoid.No further information received.
 
Additional Manufacturer Narrative
Investigation is in process.A follow-up report will be provided upon availability of additional information.
 
Additional Manufacturer Narrative
Additional information: b5, g3, h6.
 
Event or Problem Description
Update (b)(6) 24-sep-2024: further information was provided that the customer has removed the glenoid arthroscopic.It was then further reported that due to an omarthrose an additional surgery was performed and an inverse shoulder-tep was implanted.
 
Additional Manufacturer Narrative
Additional information: g3, h3, h6.Based on the information provided which may include the device (if available and returned), pictures, videos, event description, and any additional information from the field, arthrex was able to conclude a most likely cause.The most likely cause for the reported failure can be attributed to a patient-specific event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ECLIPSE CAGE SCREW L, 40MM
Common Device Name
TOT ANAT SHOULDR PROSTH, UNCEM
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key20256834
Report Number1220246-2024-07745
Device Sequence Number7987744
Product Code QHQ
UDI-Device Identifier00888867059948
UDI-Public(01)00888867059948(17)180228(10)2501279907
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K183194
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Company Representative
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup,Followup
Report Date (Section B) 05/27/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date02/28/2018
Device Model NumberECLIPSE CAGE SCREW L, 40MM
Device Catalogue NumberAR-9301-03
Device Lot Number2501279907
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/09/2024
Supplement Date Received by Manufacturer09/24/2024
05/12/2025
Initial Report FDA Received Date09/19/2024
Supplement Report FDA Received Date10/07/2024
05/27/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-