• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. ARTHREX ECLIPSE HUMERAL HEAD, 43/16; TOT ANAT SHOULDR PROSTH, UNCEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. ARTHREX ECLIPSE HUMERAL HEAD, 43/16; TOT ANAT SHOULDR PROSTH, UNCEM Back to Search Results
Model Number ARTHREX ECLIPSE HUMERAL HEAD, 43/16
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code Failure of Implant (1924)
Date of Event 09/01/2016
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a revision surgery was necessary on (b)(6) 2016 after the initial implantation on (b)(6) 2013 due to a broke out glenoid.No further information received.
 
Additional Manufacturer Narrative
Investigation is in process.A follow-up report will be provided upon availability of additional information.
 
Event or Problem Description
Update dw 24-sep-2024: further information was provided that the customer has removed the glenoid arthroscopic.It was then further reported that due to an omarthrose an additional surgery was performed and an inverse shoulder-tep was implanted.
 
Additional Manufacturer Narrative
Additional information: g3, h3, h6 based on the information provided which may include the device (if available and returned), pictures, videos, event description, and any additional information from the field, arthrex was able to conclude a most likely cause.The most likely cause for the reported failure can be attributed to a patient-specific event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARTHREX ECLIPSE HUMERAL HEAD, 43/16
Common Device Name
TOT ANAT SHOULDR PROSTH, UNCEM
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key20266283
Report Number1220246-2024-07771
Device Sequence Number20898335
Product Code QHQ
UDI-Device Identifier00888867060005
UDI-Public(01)00888867060005(11)110404(17)140930(10)0942011
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K183194
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Company Representative
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup,Followup
Report Date (Section B) 05/27/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date09/30/2014
Device Model NumberARTHREX ECLIPSE HUMERAL HEAD, 43/16
Device Catalogue NumberAR-9343-16
Device Lot Number0942011
Was Device Available for Evaluation? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/09/2024
Supplement Date Received by Manufacturer09/24/2024
05/12/2025
Initial Report FDA Received Date09/20/2024
Supplement Report FDA Received Date10/07/2024
05/27/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured04/04/2011
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-