EXACTECH, INC. LOGIC TIBIA PS MOD INSRT SZ 4 9MM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
02-012-35-4009 |
| Medical Device Problem Code |
Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Emotional Changes (1831); Pain (1994); Discomfort (2330); Osteolysis (2377); Swelling/ Edema (4577)
|
| Date of Event |
11/17/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Legal case ¿ (b)(4).It was reported via legal documentation that approximately 129 months after a left total knee replacement procedure, the patient underwent a revision procedure to address prosthesis wear.No further issues or complications were reported.No additional information is available.The serial number (b)(6) is confirmed to be a part of recall number: z-0021-2022.
|
| |
|
Additional Manufacturer Narrative
|
|
Concomitants: 2533719 , 02-010-01-0240 - logic femoral ps cem left sz 4.2520474 or 2520487 , 02-012-41-4040 - logic tibia traptray cem sz 4f/4t.2527255 or 2533381, 200-02-35 - three peg patella 35mm.The product associated with the reported event is within the scope of recall z-0021-2022.However, there is insufficient information to evaluate whether the subject issue of the recall was a cause or contributor to the reported event.The device was not returned for evaluation and no medical or other records containing treatment information or patient information have been received; therefore, the reported event cannot be confirmed, nor can the circumstances or potential causes or contributors to the alleged event be evaluated.Should additional, material information become available that permits more analysis or conclusions, a supplemental report will be filed accordingly.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and/or corrected information.The following sections were updated/corrected: h6.Mdr section codes updated/corrected: b.The reason for the revision reported cannot be confirmed from the information provided but may be the result of prosthesis wear and loosening or due to inclusion of the polyethylene in the packaging recall.Additionally, these devices appear to have been implanted for over ten years prior to the reported event.Potential contributions of user and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and images, radiographs and relevant clinical information were not provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|