EXACTECH, INC. LOGIC TIBIA IMPLANT PSC INSERT, SZ 3, 9MM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
02-012-44-3009 |
| Medical Device Problem Code |
Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Scar Tissue (2060); Osteolysis (2377); Bone Shedding Debris (4557)
|
| Date of Event |
08/15/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Concomitants: (b)(6) 02-010-01-0330 - logic femoral ps cem right sz 3, (b)(6) 02-012-41-3030 - logic tibia traptray cem sz 3f/3t.The device was not returned for evaluation and no medical or other records containing treatment information or patient information have been received; therefore, the reported event cannot be confirmed, nor can the circumstances or potential causes or contributors to the alleged event be evaluated.Should additional, material information become available that permits more analysis or conclusions, a supplemental report will be filed accordingly.(b)(6) 200-02-32 - three peg patella 32mmm.
|
| |
|
Event or Problem Description
|
|
Legal case ¿ usa.(b)(4) is associated with this case.It was reported that approximately 124 months after a right total knee replacement procedure, the patient underwent a revision procedure to address prosthesis wear, osteolysis, fragmentation of patella.Revision surgery operative notes were provided.Patient left the operating room in stable condition.No further issues or complications were reported.No additional information is available.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and/or corrected information.The following sections were updated/corrected: d4, h4, h6.Mdr section codes updated/corrected: b, e.D4: serial number is unknown.D4/h4: expiration and manufactured dates are unknown.The reason for the revision reported cannot be confirmed from the information provided but may be the result of prosthesis wear and loosening or due to inclusion of the polyethylene in the packaging recall.Additionally, these devices appear to have been implanted for over ten years prior to the reported event.Potential contributions of manufacturing, user, and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and images, radiographs and product information were not provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|