| Model Number |
OPTI0930CSFMX |
| Medical Device Problem Codes |
Migration (4003); Premature Separation (4045)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
08/27/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
It was reported that: " sex: unknown disease name: 9mm direct ccf, davf procedure: planned procedure micro catheter: unknown assist stent: unknown y connector: unknown used coils: 1st coil/optimax 9×30, 2nd coil/optimax 6×20 the physician attempted to deploy the optimax 9×30 as the 1st coil.During deployment, the physician considered that the coil size was large, so he decided to retrieve it.While retrieving the optimax 9×30, the implant coil did not follow, and was unintentionally deployed within the parent vessel.Fortunately, the unintended deployment of the implant coil resulted in the occlusion of the target blood flow as desired.(it will be reported as (b)(4).) after that, the physician chose the optimax 6x20 as the 2nd coil.The physician attempted to deploy the coil within the lesion site, but he finally decided to retrieve it.While retrieving the optimax 6x20, the coil was unraveling.Therefore, the physician used a snare device to retrieve the coil and retrieved it along with the microcatheter, and the procedure was completed.(it will be reported as ya2024-0634.) the procedure did not involve tortuous anatomy.It is unknown whether the pre-use check was performed." incident report form submitted for this complaint indicates that no patient injury was sustained.
|
| |
|
Additional Manufacturer Narrative
|
|
Balt usa reference: (b)(4).An evaluation of the actual complaint sample could not be performed as device was unavailable to be return.Based on the provided information, root cause could not be definitively determined.Lack of device return prevented deeper evaluation of the reported issue.Review of the lot history records did not reveal any in-process or lot-specific issue that could account for the observation.No additional complaints against lot number f231100509 has been made for the same issue.Comprehensive analysis of this failure mode has remained subject to monitoring for any unacceptable increase in trend.The submission of this report or related information to the fda, and its release by fda, does not reflect a conclusion by the party submitting this report of the fda that the report or related information is an admission that the manufacturer, their employees, or the device caused or contributed to the reportable event.
|
| |
|
Search Alerts/Recalls
|
|