• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ETHICON INC. EB EXC GRN 4X30IN 5 S/A V-37; SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ETHICON INC. EB EXC GRN 4X30IN 5 S/A V-37; SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE Back to Search Results
Catalog Number MB66G
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Hemorrhage/Blood Loss/Bleeding (1888); Unspecified Infection (1930); Prolapse (2475)
Date of Event 01/01/2023
Type of Reportable Event Serious Injury
Event or Problem Description
Title: clinical efficacy of modified sacral fixation under leonardo da vinci robot laparoscopy for pelvic organ prolapse.The aim of this study was to analyze the clinical efficacy of modified sacral fixation under leonardo da vinci robot laparoscopy for pelvic organ prolapse (pop).Between (b)(6)2020 and (b)(6) 2021, a total of (b)(4) patients with pelvic organ prolapse (pop) were included in the study.These patients were divided into group a (laparoscopic y-mesh, (b)(4)), group b (laparoscopic sacrovaginal fixation, (b)(4)), and group c (da vinci robotic sacral fixation, (b)(4)).The subjects of the three groups were women.The average age, average prolapse time, and average deliveries were (63.16 ± 11.85) years old, (4.56 ± 1.28) years, and (2.56 ± 1.85) times in group a, respectively, (62.89 ± 10.74) years old, (4.39 ± 1.18) years and (2.46 ± 1.74) times in group b, and (62.78 ± 12.06) years old, (4.45 ± 1.12) years, (2.39 ± 1.12) times in group c.T patients in group a were treated with laparoscopic y-shaped mesh (brand: johnson & johnson, purchased in (b)(6) medical equipment sales co., ltd., (b)(6), china); both sides were interrupted sutured on the main sacral ligament complex, and the other end of the mesh was interrupted suture fixed to the anterior sacral longitudinal ligament in front of the s1 vertebral body by using the non-absorbable suture of aixibang mb66 (mb66g, johnson & johnson, (b)(6) medical equipment co., ltd.,(b)(6), china).The patients in group b were treated with modified mesh sacral fixation using two boot-shaped mesh (johnson & johnson, purchased in (b)(6) medical equipment sales co., ltd., (b)(6), china).Reported complications in group a include hemorrhagic (n=3), infection (n=2), mesh exposure (n=3), and recurrence (n=2).In group b include hemorrhagic (n=1) and mesh exposure (n=1).In conclusion, the efficacy of modified sacral fixation under leonardo da vinci robot laparoscopy for pop was comparable to that of laparoscopic y-mesh treatment and laparoscopic sacral vaginal fixation.However, da vinci¿s robotic sacral fixation had the advantages of less intraoperative bleeding and faster postoperative recovery, which helped patients recover quickly and improved their quality of life.
 
Additional Manufacturer Narrative
(b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.An attempt has been made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Does the surgeon believe that any of the ethicon products involved caused and/or contributed to the post-operative complications described in the article? which specific ethicon products have been used during the procedures (product code, lot number)? does the surgeon believe there was any deficiency with any of the ethicon products used in this procedure? if so, please provide details.Were the cases discussed in this article previously reported to ethicon? if yes, please provide a complaint reference number.Patient demographics? this report is related to a journal article; therefore, no product will be returned for analysis and the batch history records cannot be reviewed as the lot number has not been provided.H6 component code: g07002 ¿ device not returned.D4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.The single complaint was reported with multiple events.There are no additional details regarding the additional events.Citation: european review for medical and pharmacological sciences 2023; 27: 6215-6222.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EB EXC GRN 4X30IN 5 S/A V-37
Common Device Name
SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE
Manufacturer (Section D)
ETHICON INC.
1000 route 202
raritan NJ 08869
Manufacturer (Section G)
ETHICON INC.
Manufacturer Contact
elba bello
1000 route 202
raritan, NJ 08869
9083863534
MDR Report Key20335633
Report Number2210968-2024-10404
Device Sequence Number9592294
Product Code GAT
UDI-Device Identifier10705031046290
UDI-Public10705031046290
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K946173
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Literature,Health Professional
Initial Reporter Occupation Other
Type of Report Initial
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue NumberMB66G
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/13/2024
Initial Report FDA Received Date09/30/2024
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexFemale
-
-