| Catalog Number |
00596403210 |
| Medical Device Problem Code |
Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Failure of Implant (1924); Pain (1994); Synovitis (2094); Osteolysis (2377); Swelling/ Edema (4577)
|
| Date of Event |
09/06/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).D10: item# 00597206532; lot# 65270022 item# 00598603702; lot# j6817421 customer has indicated that the product is in process of being returned to zimmer biomet for investigation.Once the investigation has been completed, a follow-up mdr will be submitted.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient underwent a revision approximately two (2) years and six (6) months post-implantation where only the patella and articular surface components were replaced.The physician suspected backside wear of the articular surface and tibia to be the cause.The patella also showed radiographic signs of bone lysis, so the surgeon wanted to replace it.Attempts have been made and no further information has been provided.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.The following sections were updated/corrected: a1; b4; b5; d2; g1; g3; g6; h1; h2; h10 d10: item# 00597206532; lot# 65270022 item# 00598603702; lot# j6817421 item# 00576401552; lot# 65022207 if any further information which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
No further event information available at the time of this report.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.The following sections were updated/corrected: a1; b4; b5; b7; d2; d9; e1; g1; g3; g6; h1; h2; h3; h6.Visual inspection of the returned articular surface exhibits signs of use (micro motion) and confirms wear/deformation visible.Primary notes suggest no intra operative complication.Revision notes states that patient was revised due to pain, swelling, synovitis.During the surgery, wear was seen underside of articular surface with some micro marking on the tibial component too.However, the tibial component was well fixed and was not explanted.Review of the device history record identified no deviations or anomalies during manufacturing.Root cause cannot be determined.This complaint is confirmed via product returned, operative notes and photographs provided.If any further information which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
No further event information available at the time of this report.
|
| |
|