Catalog Number SARP-30
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Mitral Valve Insufficiency/ Regurgitation (4451)
Date of Event 09/04/2024
Type of Reportable Event Serious Injury
Event or Problem Description
The article "valve-in-ring transcatheter mitral valve replacement in a fluoroscopically invisible ring" was reviewed.The article presented a case study of a 84-year-old man who underwent mitral annuloplasty with a 30-mm seguin ring in 2002 developed severe mitral regurgitation (mr).Echocardiography showed left ventricular ejection fraction of 40%, severe mr with an effective regurgitant orifice area of 0.4 cm2, diminutive posterior mitral valve leaflet, and a mitral valve gradient of 17/5 mm hg.He was deemed high risk for repeat surgery and anatomically unfavorable for transcatheter edge-to-edge repair.Heart team consensus was to perform valve-in-ring transcatheter mitral valve replacement.Given the proximity of the left circumflex artery (lcx) to the mitral annulus, during preprocedure computed tomography analysis, its course along the circumference of the seguin ring and deployment angle was determined.The mitral annular area was 553.6 mm2 , and a 29-mm sapien 3 (edwards lifesciences) transcatheter heart valve (thv) was chosen.Anterior mitral leaflet modification was not required given the fact that the neo¿left ventricular outflow tract area was 500 mm.A coronary wire was first positioned in the lcx.After transseptal puncture with the versacross system (boston scientific), optimal thv positioning and deployment were determined using a combination of transesophageal echocardiography, fluoroscopy with the lcx wire as a landmark in proximity to the seguin ring, and an arteriogram and ventriculogram to demarcate the atrioventricular groove there was no residual mr or left ventricular outflow tract obstruction.In conclusion, this case demonstrated that lcx wiring potentially enhances procedural precision.If implantation depth is determined using this technique, it is important to pay attention to the relationship of the lcx and annuloplasty ring using the preprocedural computed tomography scan.Any mismatch must then be taken into consideration in the catheterization laboratory when deploying the thv.[the primary and corresponding author was simon cheung-chi lam md, cardiology division, department of medicine, queen mary hospital, the university of hong kong, 102 pok fu lam road, pok fu lam, hong kong island, hong kong.E-mail: drsimonlam@gmail.Com].
 
Additional Manufacturer Narrative
Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.Literature attachment: article titled "valve-in-ring transcatheter mitral valve replacement in a fluoroscopically invisible ring".
 
Additional Manufacturer Narrative
As reported in a research article, a case study of a 84-year-old man who underwent mitral annuloplasty with a 30-mm seguin ring in 2002 developed severe mitral regurgitation (mr).Echocardiography showed left ventricular ejection fraction of 40%, severe mr with an effective regurgitant orifice area of 0.4 cm2, diminutive posterior mitral valve leaflet, and a mitral valve gradient of 17/5 mm hg.Heart team consensus was to perform valve-in-ring transcatheter mitral valve replacement as the patient was deemed high risk for repeat surgery and anatomically unfavorable for transcatheter edge-to-edge repair.Given the proximity of the left circumflex artery (lcx) to the mitral annulus, during pre-procedure computed tomography analysis, its course along the circumference of the seguin ring and deployment angle was determined and a 29 mm non-abbott transcatheter heart valve was chosen.In conclusion, this case demonstrated that lcx wiring potentially enhances procedural precision.If implantation depth is determined using this technique, it is important to pay attention to the relationship of the lcx and annuloplasty ring using the preprocedural computed tomography scan.A more comprehensive assessment could not be performed as the event was non-contemporaneously reported through a literature review and no device was received for analysis.Based on the information received, the cause of the reported incident could not be conclusively determined.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SJM SéGUIN SEMI-RIGID ANNULOPLASTY RING
Common Device Name
RING, ANNULOPLASTY
Manufacturer (Section D)
ABBOTT MEDICAL
5050 nathan lane n
plymouth MN 55442
Manufacturer (Section G)
ABBOTT MEDICAL REG# 2648612
lot 20 b st caguas
caguas 00725
*   00725
Manufacturer Contact
karen krouse
5050 nathan lane n
plymouth, MN 55442
6517565400
MDR Report Key20352159
Report Number2135147-2024-04836
Device Sequence Number7999969
Product Code KRH
UDI-Device Identifier05415067044815
UDI-Public05415067044815
Combination Product (Y/N)N
Initial Reporter CountryHK
PMA/510(K) Number
K092310
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Literature
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 10/11/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue NumberSARP-30
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 09/09/2024
Supplement Date Received by Manufacturer10/10/2024
Initial Report FDA Received Date10/02/2024
Supplement Report FDA Received Date10/11/2024
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age84 YR
Patient SexMale
-
-