| Catalog Number |
100300293 |
| Medical Device Problem Code |
Defective Device (2588)
|
| Health Effect - Clinical Code |
Eye Injury (1845)
|
| Date of Event |
09/06/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(6).H.10 reflects all related report numbers associated with this product event that have been submitted at this time.
|
| |
|
Event or Problem Description
|
|
A physician reported that after glaucoma shunt implantation procedure, there was detachment of descemet membrane.He reported that it was the first time that the surgeon was using the microstent.He incised trabecular meshwork with the tip of a cannula and inserted it into schlemm canal.However, he felt that the cut was difficult, because the tip of the cannula was bigger than he expected or he felt the tip was not sharp but dull; it was too dull to make an incision.He considers that those factors would affect the detachment of descemet membrane.Currently there has been no treatment plan for the patient.Additional information was requested, but no further information is available.There are two medical device reports associated with this report.This is 2 of 2.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information was provided in.The manufacturer internal reference number is: (b)(4).H.10 reflects all related report numbers associated with this product event that have been submitted at this time.
|
| |
|
Event or Problem Description
|
|
A physician reported that after glaucoma shunt implantation procedure, there was detachment of descemet membrane.He reported that it was the first time that the surgeon was using the microstent.He incised trabecular meshwork with the tip of a cannula and inserted it into schlemm canal.However, he felt that the cut was difficult, because the tip of the cannula was bigger than he expected or he felt the tip was not sharp but dull; it was too dull to make an incision.He considers that those factors would affect the detachment of descemet membrane.Currently there has been no treatment plan for the patient.According to the additional information received, the affected eye was right eye.The patient had history of exfoliation glaucoma (primary disease) and cataract (concomitant disease).The patient condition has been recovering.The type of procedure performed was cataract surgery + glaucoma shunt insertion.There are two medical device reports associated with this report.This is 2 of 2.
|
| |
|