Model Number 5420
Medical Device Problem Code Material Integrity Problem (2978)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/11/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Block h4: the complainant was unable to provide the suspect device lot number; therefore, the lot expiration and device manufacture dates are unknown.Block h6: imdrf impact code f1001 is being used to capture the reportable issue of aborted/cancelled procedure.
 
Event or Problem Description
Note: this report pertains to one of two devices used during the same procedure.Refer to manufacturer report # 3005099803-2024-04963 for the associated device information.It was reported to boston scientific corporation that two habib endohpb cables were used in the biliary to treat a tumor during a radiofrequency ablation (rfa) procedure performed on (b)(6) 2024.During the procedure, when connecting to the erbe generator and the habib endohpb catheter, there was no energy delivered, and there was no blanching of the tissue noted.Subsequently, upon troubleshooting, it was noted that there was no problem with the habib catheter; however, the two habib cables were both broken, causing the habib catheter to be unable to deliver energy.The procedure was cancelled, and the patient will reportedly come back at a later date.There were no patient complications reported as a result of this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HABIB ENDOHPB
Common Device Name
UNIT, ELECTROSURGICAL, ENDOSCOPIC (WITH OR WITHOUT ACCESSORIES)
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
STATICE MANUFACTURING
9 rue thomas edison
besancon 25000
FR   25000
Manufacturer Contact
carole morley
300 boston scientific way
marlborough, MA 01752
5086834015
MDR Report Key20369892
Report Number3005099803-2024-04964
Device Sequence Number3890375
Product Code KNS
UDI-Device Identifier08714729982548
UDI-Public08714729982548
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K231533
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 10/04/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number5420
Device Catalogue Number2244-02
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/11/2024
Initial Report FDA Received Date10/04/2024
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-