|
EXACTECH, INC. NV CROWN CUP CLSTR HOLE 52MM GROUP 2; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, CEMENTED
|
Back to Search Results |
|
| Catalog Number |
180-01-52 |
| Medical Device Problem Codes |
Loosening of Implant Not Related to Bone-Ingrowth (4002); Migration (4003)
|
| Health Effect - Clinical Codes |
Synovitis (2094); Osteolysis (2377); Implant Pain (4561)
|
| Date of Event |
09/10/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Concomitants: "(b)(6), 180-01-52 - nv crown cup clstr hole 52mm group 2.(b)(6), 180-65-25 - alteon 6.5mm screw, 25mm.(b)(6), 188-00-05 - wedge plasma s/o sz 5.(b)(6), 142-36-00 - cocr fem head 36mm +0 offset 12/14.(b)(6), 101-05-30 - 3.2mm drill bit30mm 1pk.The device was not returned for evaluation and no medical or other records containing treatment information or patient information have been received; therefore, the reported event cannot be confirmed, nor can the circumstances or potential causes or contributors to the alleged event be evaluated.Should additional, material information become available that permits more analysis or conclusions, a supplemental report will be filed accordingly.
|
| |
|
Event or Problem Description
|
|
Legal case ¿ usa it was reported that approximately 92 months after a left total hip replacement procedure, the patient underwent a revision procedure to address prosthesis wear, synovitis, osteolysis.Revision surgery operative notes were provided.Patient left the operating room in stable condition.No further issues or complications were reported.No additional information is available.The serial number (b)(6) is confirmed to be a part of recall number: z-1732-2022.
|
| |
|
Additional Manufacturer Narrative
|
|
Based on the available information, the patient meets the following risk criteria for early prosthesis wear and/or osteolysis: implanted with a lateralized liner, combination of largest available femoral head and/or thinnest available acetabular liner was used and implanted with a component having a shelf age of greater than 2 years.The most likely cause for the reported revision due to prosthesis wear and osteolysis may have been a combination of risk factors such as use error, implant positioning, implant size selection, and patient factors (fitness for surgery, biomechanics, activity level and local tissue oxidation potential).However, this cannot be confirmed as the devices were not returned for evaluation, and images and radiographs were not provided.H6: corrected health effect, medical device and investigation clinical codes.
|
| |
|
Search Alerts/Recalls
|
|
|