| Catalog Number |
03.233.006 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
09/11/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2024, the item was observed to be broken intra-operatively.The device was utilized with no adverse effects intra-operatively nor delays in the case.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H11 additional narrative: added: d9.H3, h6: the product was returned to j&j medtech orthopaedics for evaluation.¿visual inspection of the returned device revealed that the aiming arm radiolucent had both of the hooks of the latch broken.Fragments were not returned.No other issues were found.Therefore, the reported condition can be confirmed.A potential cause cannot be established with the provided information due to be a multifactorial issue.The semi-extended parapatellar approach surgical technique guide was reviewed.Following relevant statements were found.Precautions: -ensure that the connection between the nail and the insertion handle is tight.Retighten, if necessary, after hammering and prior to the attachment of the aiming arm.-do not attach the aiming arm to the insertion handle at this point.-do not exert forces on the aiming arm.These forces may prevent breakage of the device.Based on the investigation findings, the primary cause was related to the users hammering with the aiming arm in place or actually hitting on the aiming arm.A dimensional inspection was unable to be performed due to post manufacturing damage.A functional evaluation was unable to be performed due to post manufacturing damage.The overall complaint was confirmed as the observed condition of the aiming arm radiolucent would contribute to the complained device issue.Based on the investigation findings, and it has been determined that no corrective and/or preventative action is proposed.There is no indication that a design or manufacturing issue has caused the reported complaint condition.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device history lot: part number: 03.233.006.Lot number: 124p989.Manufacturing site: haegendorf.Release to warehouse date: 14th may 2021.A manufacturing record evaluation was performed for the finished device lot number, and no non-conformances were identified.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H11 additional narrative: added: d10.H3, h4, h6: the product was not returned to medtech orthopaedics, however photos were provided for review.During the analysis of the complaints two subcategories of the aiming arm (03.233.006) latch (60224287, drawing se_728332) failure were identified.The failure is a breakage of the carbon-fiber reinforced latch.The failure mode is an interlaminar breakage due to shear forces.Breakage is most likely favored by defects in the structure of the carbon fiber reinforced peek plate.It is in the nature of the material that the shear strength is highly anisotropic and lowest between carbon fiber layers.Likely interlaminar shear strength is reduced by defects resulting form manufacturing issues not leading to complete bond between the carbon layers.A dimensional inspection for the aim-arm radiolucent was not performed due to post manufacturing damage.As part of medtech orthopaedic quality process, all devices are manufactured, inspected, and released to approved specifications.The overall complaint was not confirmed as the observed condition of the aim-arm radiolucent would contribute to the complained device issue.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device history review: part number: 03.233.006, lot number: 124p989, manufacturing site: haegendorf, release to warehouse date: 14th may 2021, a manufacturing record evaluation was performed for the finished device lot number, and no non-conformances were identified.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|