This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Device was used for treatment, not diagnosis.H11 additional narrative: e3: reporter is a j&j sales representative.H4: the device manufacture date is currently unavailable.Investigation summary: the product has not returned to j&j medtech orthopaedics, however photos were provided for review.The photographs attached were reviewed, the ideal shuttle 45 degrees right -g had only the guidewire visible, the distal end was found broken at the loop part.The overall complaint was confirmed as the observed condition of the ideal shuttle 45 degrees right -g would contribute to the complained device issue.Based on the investigation findings, the potential cause can be traced to the procedural variables, such handling of the device or product interaction during procedure.As per instructions for use (ifu); the shuttle should be retracted when pushing the needle through tissue.Failure to retract the shuttle could result in device damage and/or patient injury.Use instructions advice to (1) inspect the ideal suture shuttle and shuttle prior to use to ensure proper mechanical function.(2) check to ensure proper function by deploying the shuttle loop through the tip of the instrument shaft.(3) retract the shuttle loop into the needle tip of the shaft (at least 5mm).The ideal suture shuttle is now ready for use.It has been determined that no corrective and/or preventative action is proposed.There is no indication that a design or manufacturing issue has caused the complaint condition.As part of j&j medtech orthopaedics quality process, all devices are manufactured, inspected, and released to approved specifications.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device history review: manufacturing record evaluation is not required as the reported event is not associated with the manufacturing process and/or the potential cause of the defect cannot be associated to manufacturing.
|
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.H4: the device manufacture date was reported as unknown on the initial report.Please note that the date of manufacture has been updated accordingly.
|