| Model Number |
FB-231D |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Hemorrhage/Blood Loss/Bleeding (1888); Pleural Effusion (2010); Pneumonia (2011); Pneumothorax (2012)
|
| Date of Event |
08/19/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Olympus reviewed the literature titled "safety and risk factors for bleeding complications of radial probe endobronchial ultrasound-guided transbronchial biopsy." this study aimed to evaluate the diagnostic performance and complication rate of radial ebus-guided transbronchial biopsy (tbb) and investigate risk factors associated with procedure-related bleeding events.Of 133 patients (median age, 69 years; men 57.1%) included, 41 were outpatients (30.8%).The median procedure time was 22min (iqr, 15¿31min).The diagnostic accuracy, sensitivity, and specificity for malignancy were 76.1%, 71.1%, and 100%, respectively.When the 26 patients who did not undergo tbb were included, the diagnostic accuracy for malignancy was 67.2%.¿type of adverse events/number of patients¿ event1: bleeding (grade 2 or higher) (n=21).Of 21 patients (15.8%) with procedure-related bleeding events, 18 had delphi grade 2 bleeding events, and only 3 had delphi grade 3 bleeding events.Epinephrine was used in 19 patients, and a balloon blocker was used in one of them for bleeding control.Event2: pneumonia (n=5).No treatment information was provided.Event3: pneumothorax (n=3).Two of the three patients required percutaneous catheter placements.The other patient required no intervention.Event4: complicated pleural effusion (n=2).No treatment information was provided.
|
| |
|
Additional Manufacturer Narrative
|
|
The representative model chosen for the biopsy forceps is fb-231d.The event date was reported as the publication date of the literature.This report is related to (b)(6).The evaluation of the event is ongoing.Should additional relevant information become available, a supplemental report will be submitted.
|
| |
|
Event or Problem Description
|
|
The following, additional information was received from the facility.It is unknown, if an olympus device cause or contribute to the adverse event described in the article or if an olympus device malfunction, during any procedure described in the article.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being supplemented to provide additional information, based on the legal manufacturer's final investigation and to provide additional information received (b5).The device history record was unable to be reviewed for this device, since the serial and/or lot number was not provided.However, olympus only releases products to market that meet all manufacturing specifications and final product release criteria.Based on the results of the investigation, it is likely, that the reported event is an accident or a complication associated with a procedure using the subject device.There was no complaint reported on the subject device.There is no evidence of an olympus device malfunction.Therefore, the root cause cannot be determined.Olympus will continue to monitor field performance for this device.
|
| |
|