EXACTECH, INC. EQUINOXE CAGE GLENOID MEDIUM, BETA; PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED
|
Back to Search Results |
|
| Catalog Number |
314-13-13 |
| Medical Device Problem Codes |
Unstable (1667); Naturally Worn (2988); Loosening of Implant Not Related to Bone-Ingrowth (4002)
|
| Health Effect - Clinical Codes |
Emotional Changes (1831); Pain (1994); Discomfort (2330); Osteolysis (2377); Ambulation or Postural Difficulties (2544); Balance Problems (4401); Joint Laxity (4526); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
10/06/2021
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
D10: ((b)(6)), 300-10-45 - equinoxe replicator plate 4.5mm o/s; ((b)(6)), 310-02-47 - equinoxe, humeral head tall, 47mm (beta); ((b)(6)), 300-20-02 - equinox square torque define screw drive kit; ((b)(6)), 300-01-13 - equinoxe, humeral stem primary, press fit 13mm.The product associated with the reported event is within the scope of recall z-1413-2024; however, there is insufficient information to evaluate whether the subject issue of the recall was a cause or contributor to the reported event.The device was not returned for evaluation and no medical or other records containing treatment information or patient information have been received; therefore, the reported event cannot be confirmed, nor can the circumstances or potential causes or contributors to the alleged event be evaluated.Should additional, material information become available that permits more analysis or conclusions, a supplemental report will be filed accordingly.
|
| |
|
Event or Problem Description
|
|
It was reported via legal documentation that approximately 93 months after a left total shoulder replacement procedure, the patient underwent a revision procedure to address loosening, significant increased pain exacerbated with all activities in his left shoulder.Post operative diagnosis noted wear of the implant.No further issues or complications were reported.No additional information is available.
|
| |
|
Additional Manufacturer Narrative
|
|
The reason for the revision reported cannot be confirmed from the information provided but may be the result of prosthesis wear, glenoid loosening, and/or due to inclusion of the polyethylene in the packaging recall.Potential contributions of user and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and images, radiographs, and relevant clinical information were not provided.D6: corrected h6: corrected health effect, medical device and investigation clinical codes.
|
| |
|