Catalog Number 0210012000
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Codes Foreign Body In Patient (2687); Insufficient Information (4580)
Date of Event 09/30/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This record is a consolidation of records summarized as a part of the fda voluntary malfunction summary reporting program.Reported events 2 events were reported for this quarter.Product return status 2 devices were not available for evaluation.Additional information 2 devices were labeled for single-use.2 devices were not reprocessed or reused.
 
Event or Problem Description
This report summarizes 2 malfunction events in which the device had a component detach.2 events had insufficient information received.
 
Event or Problem Description
This report summarizes 2 malfunction events in which the device had a component detach.2 events had insufficient information received regarding health impact.
 
Additional Manufacturer Narrative
This record is a consolidation of records summarized as a part of the fda voluntary malfunction summary reporting program.Supplemental rationale: corrected data: b5, h6, h11.2 previously reported events are included in this follow-up record.Product return status: 2 devices were not available for evaluation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SOFT TISSUE TIP
Common Device Name
LAVAGE, JET
Manufacturer (Section D)
STRYKER INSTRUMENTS-A DIVISION OF STRYKER CORP
1941 stryker way
portage MI 49002
Manufacturer (Section G)
STRYKER INSTRUMENTS-PUERTO RICO
las palmas industrial park
highway #3, km 130.2
arroyo 00615
*   00615
Manufacturer Contact
kelsey barla
1941 stryker way
portage, MI 49002
2693237700
MDR Report Key20504461
Report Number3015967359-2024-02202
Device Sequence Number12862192
Product Code FQH
UDI-Device Identifier04546540144171
UDI-Public04546540144171
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
Exemption NumberVMSR
Number of Events Summarized2
Summary Report (Y/N)Y
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 07/28/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue Number0210012000
Device Lot NumberVMSR
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 09/30/2024
Supplement Date Received by Manufacturer09/30/2024
Initial Report FDA Received Date10/22/2024
Supplement Report FDA Received Date07/28/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-