U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDTRONIC, INC. CRYOCONSOLE; SURGICAL DEVICE, FOR CUTTING, COAGULATION, AND/OR ABLATION OF TISSUE, INCLUDING

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC, INC. CRYOCONSOLE; SURGICAL DEVICE, FOR CUTTING, COAGULATION, AND/OR ABLATION OF TISSUE, INCLUDING Back to Search Results
Model Number 65CS1
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Arrhythmia (1721)
Date of Event 10/05/2024
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Event or Problem Description
The patient had a concomitant surgical procedure of mitral valve repair through minimally invasive thoracotomy.During the same procedure on the ((b)(6) 2024) a cryoflex probe powered by a cryoconsole, and a cardioblate lp clamp powered by a cardioblate generator were used.The left atrial appendage was closed.The left pulmonary vein (lpv) was not performed due to the thoracotomy surgical approach.The right pulmonary vein (rpv) conduction block was successfully achieved.On the ((b)(6) 2024) the patient experienced sinus node dysfunction.Sinus node dysfunction (bradycardia) with av block vs blocked premature atrial contractions (pacs) was noted on telemetry while admitted from the index procedure.Antiarrhythmic medications being held due to contraindication with rhythm.A pacemaker was inserted.The patients outcome status was recovering/resolving.The adverse event was deemed by the site as possibly related to the cardioblate lp clamp, the cryoflex probe, the concomitant procedure, the study procedure and the study device.The adverse event was deemed by the sponsor as possibly related to the cardioblate lp clamp, the cryoflex probe and the cardioblate cryoflex console and related to the concomitant procedure and study procedure.
 
Additional Manufacturer Narrative
Medtronic received additional information that the adverse event is possibly related to the study device due to the rf prob not articulating the jaw and it is difficult to use in mini thoracotomy cases.Hence, the cryo probe had to be used for lesions.The rf probe could not be used for ras lesions, therefore the cryo probe was used.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CRYOCONSOLE
Common Device Name
SURGICAL DEVICE, FOR CUTTING, COAGULATION, AND/OR ABLATION OF TISSUE, INCLUDING
Manufacturer (Section D)
MEDTRONIC, INC.
3800 annapolis lane
minneapolis MN 55447
Manufacturer (Section G)
MEDTRONIC, INC.
3800 annapolis lane
minneapolis MN 55447
Manufacturer Contact
alison sweeney
parkmore business park west
galway 
EI  
091708096
MDR Report Key20512744
Report Number3008592544-2024-00087
Device Sequence Number7203844
Product Code OCL
UDI-Device Identifier00763000014988
UDI-Public00763000014988
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
K121878
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Study,Health Professional,User Facility
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 11/21/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number65CS1
Device Catalogue Number65CS1
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/15/2024
Supplement Date Received by Manufacturer11/01/2024
Initial Report FDA Received Date10/23/2024
Supplement Report FDA Received Date11/21/2024
Date Device Manufactured07/23/2019
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age48 YR
Patient SexMale
Patient Weight99 KG
-
-