• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ICU MEDICAL DE MEXICO, S. DE R.L. DE C.V. 6" SMALLBORE EXT SET W/6-PORT NANOCLAVE® MANIFOLD, CHECK VALVE, CLAMP, ROTATING; STOPCOCK, I.V. SET

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ICU MEDICAL DE MEXICO, S. DE R.L. DE C.V. 6" SMALLBORE EXT SET W/6-PORT NANOCLAVE® MANIFOLD, CHECK VALVE, CLAMP, ROTATING; STOPCOCK, I.V. SET Back to Search Results
Catalog Number AM6130
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/01/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Received two (2) samples: one (1) used.List #am6130, 6" smallbore ext set w/6-port nanoclave® manifold, check valve, clamp, rotating luer.One (1) used.List #am6130, 6" smallbore ext set w/6-port nanoclave® manifold, check valve, clamp, rotating luer, one (1) used.List #unknown, microclave.As received, no physical damage or other anomalies were observed leak tested both samples, sample #1 had a small hole in the tubing where it mates with the manifold, tubing bond was sufficient.Probable cause, unintentional bending forces during use.Sample #2 noticed that the connection at the mixing valve was not secure, the male luer was not fully inserted into the female luer threads, causing the leak.Probable cause, connection not fully inserted during assembly in (b)(6).Confirmed customer complaint of leaking where the tubing meets the manifold on both returned samples.D9 - date returned to mfg: 9/16/2024.A device history review (dhr) lot # review could not be conducted because no lot number(s) was/were identified.
 
Event or Problem Description
An event on an unknown date involving a 6" smallbore ext set w/6-port nanoclave® manifold, check valve, clamp, rotating luer resulted in leakage.It was reported that their cicu had leaking issues with the am6130 manifold set.They had issues where there was leaking from one of the manifold claves.Sample is available for evaluation.There was unknown patient involvement, unknown adverse event and unknown delay in therapy.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
6" SMALLBORE EXT SET W/6-PORT NANOCLAVE® MANIFOLD, CHECK VALVE, CLAMP, ROTATING
Common Device Name
STOPCOCK, I.V. SET
Manufacturer (Section D)
ICU MEDICAL DE MEXICO, S. DE R.L. DE C.V.
avenida cuarzo no. 250
ensenada, b.cfa. 22790
MX  22790
Manufacturer Contact
reed covert
600 n. field dr.
lake forest, IL 60045
2247062300
MDR Report Key20568808
Report Number9617594-2024-01534
Device Sequence Number20639265
Product Code FMG
UDI-Device Identifier00887709087712
UDI-Public00887709087712
Combination Product (Y/N)N
Initial Reporter StateKY
Initial Reporter CountryUS
PMA/510(K) Number
K964435
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 10/30/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberAM6130
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/16/2024
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/02/2024
Initial Report FDA Received Date10/30/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-