EXACTECH, INC. LOGIC FEMORAL PS CEM RIGHT SZ 3.5; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
02-010-01-0335 |
| Medical Device Problem Code |
Loosening of Implant Not Related to Bone-Ingrowth (4002)
|
| Health Effect - Clinical Code |
Joint Laxity (4526)
|
| Date of Event |
11/21/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
D10: concomitant devices (b)(6) 02-012-35-3509 - logic tibia ps mod insrt sz 3.5 9mm.(b)(6) 02-012-45-3535 - lgc tibial fit tray cem sz 3.5f / 3.5t.(b)(6) 02-010-01-0235 - logic femoral ps cem left sz 3.5.(b)(6) 200-02-32 - three peg patella 32mm.(b)(6) 200-02-32 - three peg patella 32mm.(b)(6) 201-78-89 - 3" drill bit, mod.Hex 2 pack.(b)(6) 203-96-42 - 11-4132 stryker sys 6 90x13/21x1.19.(b)(6) 1500-s - cemex system 80g.(b)(6) asa0030 - sterile disposable containers.(b)(6) asa0030 - sterile disposable containers.The device was not returned for evaluation and no medical or other records containing treatment information or patient information have been received; therefore, the reported event cannot be confirmed, nor can the circumstances or potential causes or contributors to the alleged event be evaluated.Should additional, material information become available that permits more analysis or conclusions, a supplemental report will be filed accordingly.
|
| |
|
Event or Problem Description
|
|
Legal case: usa.Related case (b)(4) lk rev.As reported via legal documentation the patient had a right knee replacement on (b)(6) 2014.Approximately 8 years and 5 months after the initial procedure the patient had a right knee revision on (b)(6) 2022.There is no other patient demographic or medical history available.There is no device return.There are no photos or other images of the device provided.No additional information is available.Revision op report on 21 nov 2022.Principal diagnosis: failed right total knee replacement due to mechanical loosening.Post-op diagnosis: same.Significant fibrinous debris was encountered into the joint with a tandem whitish color this tissue was highly friable was found throughout the suprapatellar pouch as well as in the gutters.This was excised and the knee in order to fully debrided to visualize all the components then removes similar debris from the anterior interval as well as did are normal medial release.We then removed the polyethylene insert with a single prong retractor.The poly was noted to be yellow with significant pitting and loss of thickness in the medial lateral compartment with central pitting and roughness noted on both the medial and lateral dwell points.The femoral implant was grossly loose and was removed without any machine and.Similar fibrous debris was found under the femoral component and into the posterior lateral.This was debrided with sharp dissection as well as with the rongeur bluntly.No device return anticipated due to this being a legal case.Ebi initial surgery attached.Operative report from revision surgery attached.No further information.
|
| |
|
Search Alerts/Recalls
|
|
|