EXACTECH, INC. ADVANCED PATELLA 32MM 3 PEG IMPLANT; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
200-07-32 |
| Medical Device Problem Codes |
Naturally Worn (2988); Loosening of Implant Not Related to Bone-Ingrowth (4002)
|
| Health Effect - Clinical Code |
Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
09/23/2020
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Legal case ¿ usa.Original description summary: as reported via legal documentation the patient had a left knee replacement.Approximately 2 years and 10 months after the initial procedure the patient had a left knee revision on (b)(6) 2020.There is no other patient demographic or medical history available.There is no information on the surgical procedure or patient outcome.There is no device return.There are no photos or other images of the device provided.No additional information is available.Unable to determine right and left products.The patient has filed a complaint in a coordinated action in alachua county with master case no.(b)(6).The consolidated long form complaint that applies to cases filed in this coordinated action alleges that patients filing suits in this coordinated action were required ¿to undergo revision surgeries due to severe, pain, swelling, and instability¿ due to ¿wear of the polyethylene components and resulting component loosening and/or other failure failures causing serious complications including tissue damage, osteolysis, permanent bone loss, and other injuries.¿ because the patient has filed a short-form complaint in this coordinated action, the patient appears to allege that the patient was injured as a result of wear of an exactech polyethylene device.Additional information received from legal on 12sep2023 as reported via legal documentation the patient had a left knee replacement.Approximately 2 years and 10 months after the initial procedure the patient had a left knee revision on (b)(6) 2020.Revision op report postoperative diagnosis: aseptic loosening, left femur and patella.There was some erosion under the medial aspect of the patella and it was loose.The femoral component was checked by tapping on the anterior flange and it came loose from the cement.Cement mantle was intact.The well-fixed tibial component was removed with minimal additional bone loss.There is no other patient demographic or medical history available.There is no device return.There are no photos or other images of the device provided.No additional information is available.
|
| |
|
Additional Manufacturer Narrative
|
|
1038671-2023-02331 d10: concomitant devices: truliant psc tibial insert (02-022-35-3510, 5060501).Truliant fit tibial tray (02-022-45-3535, 4856602).Truliant femoral component (02-020-11-0235, 5046120).Manufacturer narrative: the reason for the revision reported cannot be determined from the available information but may have been reported at this later time due to inclusion of one of the implanted devices in the packaging recall.However, the reported prosthesis wear/failure, femoral loosening and patellar loosening could not be confirmed and potential contributions of user, or patient-related considerations to the event could not be assessed as no images or radiographs were provided, relevant clinical information was not provided, and the devices were not available for evaluation.
|
| |
|
Search Alerts/Recalls
|
|
|