Olympus medical systems corp.(omsc) reviewed a literature titled "predictive factors for prolonged operative time in ureteroscopic lithotripsy for ureteral stones".Literature summary introduction: a prolonged operative time of lithotripsy with ureteroscopy for urolithiasis increases the risk of infectious complications; however, few reports have investigated the factors prolonging the operative time for ureteral stones.We investigated the factors associated with longer operative time in ureteroscopy for ureteral stones.Methods: this retrospective cohort study analyzed patients who underwent retrograde ureteroscopic lithotripsy for ureteral stones and achieved an endoscopic stone-free status between april 2019 and july 2022.Patients were classified into two groups based on an operative time of =90 minutes or <90 minutes.We compared the patient and stone characteristics and surgical outcomes, and investigated the factors associated with a prolonged operative time.Results: the cohort comprised 519 patients, with 58 patients in the group with an operative time of =90 minutes.Compared to the shorter operative time group, the longer operative time group had a significantly greater proportion of males, stone diameter, stone volume, and hounsfield units of stone; additionally, the longer operative time group had higher prevalences of endoscopic findings of edema, polyps, and mucosa-stone adherence.Multivariable analysis showed that stone size >10 mm (odds ratio 4.05), polyps (odds ratio 2.40), and mucosal adherence (odds ratio 3.51) were significantly associated with an operative time exceeding 90 minutes.There were no significant differences between the two groups in the incidences of postoperative fever and systemic inflammatory response syndrome.Conclusions: stone size, endoscopic findings of polyps, and mucosa-stone adherence were independent factors associated with a longer operative time.Type of serious adverse events/number of patients sirs (systematic inflammatory response syndrome) (48 patients) ureteral injury (20 patients).
|
|
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.Additionally, to provide an update to field (d8) and to provide a correction to field (d4).Since the serial and/or lot number was not provided, the (udi) unique device identifier is unknown and have been left blank accordingly.The device history record was unable to be reviewed for this device since the serial and/or lot number was not provided.However, olympus only releases products to market that meet all manufacturing specifications and final product release criteria.Based on the results of the investigation, the reported event was likely an accident, or a complication associated with a surgical procedure while using the subject device.There was no complaint reported on the subject device and no evidence of an olympus device malfunction.Therefore, the root cause cannot be determined.Olympus will continue to monitor field performance for this device.
|