| Model Number |
VICM5_13.7 |
| Medical Device Problem Codes |
Adverse Event Without Identified Device or Use Problem (2993); No Apparent Adverse Event (3189)
|
| Health Effect - Clinical Codes |
Uveitis (2122); Visual Disturbances (2140); Halo (2227); No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
10/19/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
A facility representative reported that following an implantable collamer lens (icl) implantation procedure, excessive vault was observed.The lens remains implanted.Additional information was requested.No further information is available at this time.This file will be re-opened if additional information is provided.There are multiple medical device reports associated with this patient.This report is 1 of 2 total reports.Based on the information provided, the risk assessment for our product, and our experience, we have determined the cause or contribution to the reported issue is not indicative of a manufacturing related issue or product deficiency.
|
| |
|
Additional Manufacturer Narrative
|
|
A4-a6:unk b3: unk d4 (experiation date); unk no serial number reported.D6a: unk h4 (device manufacturing date): no serial number reported.Claim# (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
Claim# (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
B5: a facility representative reported that following an implantable collamer lens (icl) implantation procedure, a patient with pre-existing retinal holes, experienced excessive vault, glare/halos, and uvetis/iritis.Reportedly, the patient had laser retinopexy, no diabetic retinopathy, drusen.The lens remains implanted.Cause was reported as the device.There are multiple medical device reports associated with this patient.This report is 1 of 2 total reports.Based on the information provided, the risk assessment for our product, and our experience, we have determined the cause or contribution to the reported issue is not indicative of a manufacturing related issue or product deficiency.H6: work order search: 1 similar complaints within associated lots was found.Fellow eye claim# (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
H6: device history record review indicates that the product has been manufactured within the established process parameters and that there is no indication that the manufacturing and/or processing of the device contributed to the complaint issue.Claim# (b)(4).
|
| |
|