MAUDE Adverse Event Report: ALCON LABORATORIES IRELAND LTD. CLAREON VIVITY EXTENDED VISION HYDROPHOBIC IOL; EXTENDED DEPTH OF FOCUS INTRAOCULAR LENS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ALCON LABORATORIES IRELAND LTD. CLAREON VIVITY EXTENDED VISION HYDROPHOBIC IOL; EXTENDED DEPTH OF FOCUS INTRAOCULAR LENS Back to Search Results
Model Number CNWET0
Medical Device Problem Code Material Twisted/Bent (2981)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 10/09/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A product was not returned for analysis.Complaint history and product history records were reviewed and documentation indicated the product met release criteria.Root cause has not been identified.The manufacturer internal reference number is: (b)(4).H.10 reflects all related report numbers associated with this product event that have been submitted at this time.
 
Event or Problem Description
A facility representative reported that during an intraocular lens (iol) implantation procedure, noticed that the haptic was trailing in the cartridge.Surgeon was reluctant to use due to possible shearing off during procedure.The procedure was completed with another lens.Additional information was requested.
 
Additional Manufacturer Narrative
Additional information: the product was returned for analysis and the reported complaint was observed.The cartridge was returned.Viscoelastic was observed in the cartridge.The lens was advanced to the nozzle entry area.The haptics were not folded.No damage was observed.The cartridge had evidence of placement into a handpiece piece; however, it may have not been fully seated.The cartridge was cleaned for further evaluation.The lens was removed during cleaning.Topcoat dye stain testing was conducted with acceptable results.Product history records could not be reviewed because the reporter did not provide a lot number or any identification traceable to the manufacturing documentation.Qualified associated products were associated products were indicated.The file states that the iol was in the cartridge for 10-15 mins before implantation.No problem was found with the returned cartridge.Topcoat dye stain testing was conducted with acceptable results.The root cause appears to be related to a failure to follow the ifu.It was indicated the lens was in the cartridge 10-15 minutes.The haptics on the lens were not folded.The haptics may have unfolded due to the extended time in the cartridge.The ifu instructs: follow the section regarding directions for use for information on the maximum allowed time for the iol to stay in the folded condition.Failure to adhere to manufacturer¿s recommendations may result in iol damage.Ifu note: during lens loading and insertion, do not allow the iol to remain in a folded condition within the selected iol delivery system for more than 3 minutes prior to completing insertion into the capsular bag.The trailing haptic is to be manually folded by the end user.The ifu instructs: using holding forceps, grasp the lens by the optic edge and gently place the lens anterior side up into the back of the ovd-filled cartridge.The lens should be inserted until the optic is a little more than half-way inside the cartridge.Use the holding forceps to gently push down on the lens, verifying that the lens is on the bottom surface of the cartridge.Using holding forceps, take the trailing haptic, and gently fold the haptic onto the anterior side of the optic.Slowly grip or push the optic edge to position the lens as far into the cartridge as the forceps will permit, while ensuring the lens remains on the bottom surface of the cartridge and the trailing haptic remains on the optic.Failure to follow these steps may cause the lens to advance incorrectly causing delivery issues and/or damage.Based on the results from the product history record, the product (iol) met release criteria.The manufacturer internal reference number is: (b)(4).H.10 reflects all related report numbers associated with this product event that have been submitted at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CLAREON VIVITY EXTENDED VISION HYDROPHOBIC IOL
Common Device Name
EXTENDED DEPTH OF FOCUS INTRAOCULAR LENS
Manufacturer (Section D)
ALCON LABORATORIES IRELAND LTD.
cork business&technology park
model farm road
cork 00000
EI  00000
Manufacturer (Section G)
ALCON LABORATORIES IRELAND LTD.
cork business&technology park
model farm road
cork 00000
EI   00000
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key20621572
Report Number9612169-2024-01126
Device Sequence Number18361338
Product Code POE
UDI-Device Identifier00380652405249
UDI-Public(01)00380652405249(17)280519(11)240521(10)25853452
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
P190018
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 01/09/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberCNWET0
Device Catalogue NumberCNWET0.200
Device Lot Number25853452
Was Device Available for Evaluation? Device Returned to Manufacturer
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/10/2024
Supplement Date Received by Manufacturer12/16/2024
Initial Report FDA Received Date11/06/2024
Supplement Report FDA Received Date01/09/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/21/2024
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
DUOVISC OVD.; MONARCH II LOADING FORCEPS.; MONARCH III IOL CARTRIDGE D.; MONARCH III IOL INJECTOR.
Patient SexUnknown
-
-