BOLTON MEDICAL, INC TREO ABDOMINAL STENT-GRAFT SYSTEM; STENT, ENDOVASCULAR GRAFT, AORTIC
|
Back to Search Results |
|
| Catalog Number |
28-L2-17-100U |
| Medical Device Problem Codes |
Adverse Event Without Identified Device or Use Problem (2993); Failure to Seal (4070); Device Endoleak (4074)
|
| Health Effect - Clinical Code |
Clinical Endoleak (4843)
|
| Date of Event |
06/20/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
This complaint was involved with three devices.Device 1 is being reported under mdr-2247858-2024-00276, device 2 is being reported under mdr-2247858-2024-00293, and device 3 is being reported under mdr-2247858-2024-00294.Bolton medical, inc.(d/b/a terumo aortic), herein known as the "company", is submitting this report pursuant to 21 cfr part 803, has made reasonable efforts to obtain complete information, and has provided as much as is available to the company as of the submission date of this report.This report is based on information obtained by the company, which may not have been able to fully investigate or verify prior to the date the report was required by the regulations.Any required fields that are unpopulated are blank because the information is currently unknown, unavailable, or not applicable.This report does not constitute an admission or a conclusion by anyone that the device caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the certain regulations, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
| |
|
Event or Problem Description
|
|
"doctor notified me that the follow up scan has an endoleak.Additional information received on 10/17/2024: procedure was done yesterday.We never did an angio to truly see if there was a type 1a vs what i believe is a type 2.The dr.Admitted there was a probably a type 2.But wanted to treat as though there was a possible 1a also.He ended up putting in 6 endo anchors and then added a 28x40 treo cuff.Patient is doing well last i heard.".Patient outcome: "patient scheduled for follow up procedure to determine source of endoleak and treat on (b)(6) 2024".
|
| |
|
Additional Manufacturer Narrative
|
|
This complaint was involved with three devices.Device 1 is being reported under mdr-2247858-2024-00276, device 2 is being reported under mdr-2247858-2024-00293, and device 3 is being reported under mdr-2247858-2024-00294.Bolton medical, inc.(d/b/a terumo aortic), herein known as the "company", is submitting this report pursuant to 21 cfr part 803, has made reasonable efforts to obtain complete information, and has provided as much as is available to the company as of the submission date of this report.This report is based on information obtained by the company, which may not have been able to fully investigate or verify prior to the date the report was required by the regulations.Any required fields that are unpopulated are blank because the information is currently unknown, unavailable, or not applicable.This report does not constitute an admission or a conclusion by anyone that the device caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the certain regulations, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
| |
|
Event or Problem Description
|
|
"doctor notified me that the follow up scan has an endoleak.Additional information received on 10/17/2024: procedure was done yesterday.We never did an angio to truly see if there was a type 1a vs what i believe is a type 2.The dr.Admitted there was a probably a type 2.But wanted to treat as though there was a possible 1a also.He ended up putting in 6 endo anchors and then added a 28x40 treo cuff.Patient is doing well last i heard." patient outcome: "patient scheduled for follow up procedure to determine source of endoleak and treat on (b)(6) 2024".
|
| |
|