| Catalog Number |
3194108 |
| Medical Device Problem Code |
Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
10/15/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The manufacturer has received the sample and is pending evaluation.A supplemental will be submitted with evaluation results.
|
| |
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2024 i placed a powerpicc solo catheter.On (b)(4) 2024 i was called to the infusion department because the picc line was leaking.I took the dressing off and pulled the picc as i flushed it and found 2 cracks in the picc about 5cm up from the hub.The patient said his arm felt full after his last infusion.The picc line was removed and i placed a 2.25 midline in the patient so he could receive his treatment.The following day i placed another picc line in the opposite arm.No other information provided, at this time.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The complaint of a damaged catheter was confirmed.The product returned for evaluation was one 4fr single lumen powerpicc solo.The investigation findings are consistent with damage accumulated through flexural fatigue.Flexural fatigue may occur due to cyclic kinking of the catheter tube in which physiological, placement, usage, and mechanical factors may gradually form a crack(s) in the catheter.The returned product sample was evaluated and two splits were observed between the 4cm and 6cm depth markings.The catheter splits contained physical features associated with material fatigue, and the characteristics observed which supported this type of failure included: damage which was circumferentially aligned.Fracture edges which were rounded and polished due to repeated material wear.'c' shaped impressions leading into the fracture sites which are consistent with material buckling due to movement which caused the fracture edges to be pressed together.Overall elliptical shape to the fracture cross-section (a result of repeated kinking of the tubing).Repetitive kinking of the indwelling catheter appears to have contributed to the observed leak; however, the specific circumstances surrounding how kinking developed into a fracture within the catheter tubing were ultimately unknown.An examination of the catheter structure revealed no potential damage/defect related to manufacture of the product.The damage location suggested that catheter securement, access and maintenance techniques may have contributed.
|
| |
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2024 i placed a powerpicc solo catheter.On (b)(6) 2024 i was called to the infusion department because the picc line was leaking.I took the dressing off and pulled the picc as i flushed it and found 2 cracks in the picc about 5cm up from the hub.The patient said his arm felt full after his last infusion.The picc line was removed and i placed a 2.25 midline in the patient so he could receive his treatment.The following day i placed another picc line in the opposite arm.No other information provided, at this time.
|
| |
|