| Catalog Number |
701M6540 |
| Medical Device Problem Code |
Loosening of Implant Not Related to Bone-Ingrowth (4002)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
10/29/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that a vitality closure top migrated out of it's mating polyaxial screw post-operatively.The original construct was an l3/4 plif using a competitive cage.One month postoperatively, it was confirmed that the l3 left set screw was loosening, and three months after the surgery, it was confirmed that the set screw was completely popped off.A revision surgery was performed.This is report one of two for this event.
|
| |
|
Additional Manufacturer Narrative
|
|
D4: the remainder of the udi number is unknown because the lot number is not available.Without a product return, no product evaluation is able to be conducted.The lot number is unknown; therefore the device history records are unable to be reviewed.Current information is insufficient to permit a valid conclusion about the cause of this event.If additional information is obtained that adds value to the relevant content of this report and/or a conclusion can be drawn, a follow-up report will be sent.
|
| |
|
Additional Manufacturer Narrative
|
|
If additional information is obtained that adds value to the relevant content of this report, a follow-up report will be sent.Reference report 3012447612-2024-00369.
|
| |
|
Event or Problem Description
|
|
It was reported that a vitality closure top migrated out of it's mating polyaxial screw post-operatively.The original construct was an l3/4 plif using a competitive cage.One month postoperatively, it was confirmed that the l3 left set screw was loosening, and three months after the surgery, it was confirmed that the set screw was completely popped off.A revision surgery was performed.This is report one of two for this event.
|
| |
|
Additional Manufacturer Narrative
|
|
H3: "device evaluation anticipated, but not yet begun" is erroneous and no longer applies.The device was evaluated.H6: additional method code: 4110.Corrections in h3.Additional information in h6: investigation type, findings, and conclusions.Device evaluation: the returned device matches the information in the complaint file and was examined.Visual inspection revealed no signs of damage.X-ray images were provided which show that a closure top has migrated out of its screw.Root cause: a definitive root cause cannot be determined with the information provided.This event could possibly be attributed to not fully seating the closure tops against the rods.Dhr review: the dhr was reviewed.There are no indications of manufacturing issues which would have contributed to this event and the device was likely conforming when it left highridge medical¿s control.Device usage: this device is used for treatment.If additional information is obtained that adds value to the relevant content of this report, a follow-up report will be sent.
|
| |
|
Event or Problem Description
|
|
It was reported that a vitality closure top migrated out of it's mating polyaxial screw post-operatively.The original construct was an l3/4 plif using a competitive cage.One month postoperatively, it was confirmed that the l3 left set screw was loosening, and three months after the surgery, it was confirmed that the set screw was completely popped off.A revision surgery was performed.This is report one of two for this event.
|
| |
|