| Catalog Number |
3572-1 |
| Medical Device Problem Code |
Calibration Problem (2890)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
10/30/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
D4: the remainder of the udi number is unknown because the lot number is not available.D10: pathfinder nxt cnnltd 5.5 plyscrw 7.5x30, pn 3505-4545 ln 81lw without a product return, no product evaluation is able to be conducted.The lot number is unknown; therefore the device history records are unable to be reviewed.Current information is insufficient to permit a valid conclusion about the cause of this event.If additional information is obtained that adds value to the relevant content of this report and/or a conclusion can be drawn, a follow-up report will be sent.Reference reports 3012447612-2024-00370.
|
| |
|
Event or Problem Description
|
|
It was reported that during the final tightening of a set screw, the torque wrench clicking sound was sluggish and the set screw was damaged.The set screw was replaced, however the second set screw was damaged in the same way.The bone screw was removed and replaced with a new screw, and the final tightening of the set screw was successful.This caused a 15 minute delay to the procedure, however there was no patient impact.This is report three of three for this event.
|
| |
|
Additional Manufacturer Narrative
|
|
Corrections in b5 and d10.If additional information is obtained that adds value to the relevant content of this report, a follow-up report will be sent.Reference reports 3012447612-2024-00370 through 3012447612-2024-00372 and 3012447612-2025-00021 through 3012447612-2025-00022.
|
| |
|
Event or Problem Description
|
|
It was reported that during the final tightening of a set screw, the torque wrench clicking sound was sluggish and the set screw was damaged.The set screw was replaced, however the second and third set screws were damaged in the same way.The bone screw was also damaged, and removed and replaced with a new screw, and the final tightening of the set screw was successful.This caused a 15 minute delay to the procedure, however there was no patient impact.This is report three of five for this event.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information in h6: investigation type, findings, and conclusions.Device evaluation: the device was not returned and no photos were provided, so an evaluation is unable to be performed.Root cause: a definitive root cause cannot be determined with the information provided.This event could possibly be attributed to loss of calibration through use over time.Dhr review: the lot number was not reported and the device was not returned, therefore a dhr review is unable to be performed.Device usage: this device is used for treatment.If additional information is obtained that adds value to the relevant content of this report, a follow-up report will be sent.
|
| |
|
Event or Problem Description
|
|
It was reported that during the final tightening of a set screw, the torque wrench clicking sound was sluggish and the set screw was damaged.The set screw was replaced, however the second and third set screws were damaged in the same way.The bone screw was also damaged, and removed and replaced with a new screw, and the final tightening of the set screw was successful.This caused a 15 minute delay to the procedure, however there was no patient impact.This is report three of five for this event.
|
| |
|