Catalog Number 0620040690
Medical Device Problem Codes Decrease in Pressure (1490); Output Problem (3005)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/01/2024
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that there was loss of insufflation.
 
Additional Manufacturer Narrative
Additional information will be provided once the investigation has been completed.The device manufacturer date is not known at this time.However, should it become available it will be provided in future reports.
 
Additional Manufacturer Narrative
This complaint investigation was closed based on the device not received, therefore the reported failure mode was not confirmed.In the event that the device is received, the complaint will be reopened and the investigation will be updated with new results.Alleged failure: loss of insufflation.Probable root cause: 1.Pressure sensor malfunction / out of calibration 2.Software malfunction 3.Use error 4.System design 5.Unwanted movement of internal components / wiring 6.Power button inadvertently turned off 7.Tubeset/gas supply inadvertently detached/loose 8.Loss of power 9.Pressure button does not disengage 10.Electromagnetic interference (emi) from rf communication, hf surgical instruments, esd, or power surge 11.Hpu or lpu assembly malfunction 12.Leaks from internal connections or seals 13.Ppv failure the reported failure mode will be monitored for future reoccurrence.
 
Event or Problem Description
It was reported that there was loss of insufflation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PKG, HEATED TUBESET W/RTP PNEUMO SURE 10
Common Device Name
INSUFFLATOR, LAPAROSCOPIC
Manufacturer (Section D)
STRYKER ENDOSCOPY-SAN JOSE
5900 optical court
san jose CA 95138
Manufacturer (Section G)
STRYKER ENDOSCOPY-SAN JOSE
5900 optical court
san jose CA 95138
Manufacturer Contact
lucas wolski
5900 optical court
san jose, CA 95138
4087542000
MDR Report Key20800773
Report Number0002936485-2024-00858
Device Sequence Number15161836
Product Code HIF
UDI-Device Identifier37613327055659
UDI-Public37613327055659
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K003792
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
Report Date (Section B) 02/13/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number0620040690
Device Lot Number22N0335
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 11/01/2024
Supplement Date Received by Manufacturer11/01/2024
Initial Report FDA Received Date11/27/2024
Supplement Report FDA Received Date02/13/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-