SMITH & NEPHEW, INC. NS VIS ADPT GUIDE LGNP KIT; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
V0200109 |
| Medical Device Problem Codes |
Inadequacy of Device Shape and/or Size (1583); Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Laceration(s) (1946)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Internal complaint reference (b)(4).H3, h6: this complaint was opened by smith+nephew to document a patient complication reported that includes reference to the use of a smith+nephew product without evidence about a specific product problem.The reported complication relates to known inherent procedural risks that are appropriately documented in our risk files.Smith+nephew will continue to monitor trends in accordance with our post-market surveillance process and take necessary action as required if anticipated severity and/or occurrence rates are exceeded.Smith+nephew has no reason to suspect that the product failed to meet any specifications at the time of manufacture.Based on our review of all currently available information, we are unable to confirm a relationship between the reported event and the device or identify a definitive root cause.However, as the use of our product cannot be excluded as a potential cause or contributory factor to the reported issue, we are submitting this report in accordance with applicable regulations.If additional investigative findings or information becomes available that alters the conclusions of this report, a follow-up report will be submitted as required.
|
| |
|
Event or Problem Description
|
|
It was reported that, during a tka surgery, the visionaire cut guide cut more tibia than it should have.It is unknown how the surgery was completed or if this caused a surgical delay.The patient current health status is unknown.
|
| |
|
Event or Problem Description
|
|
It was reported that, during a tka surgery, the visionaire cut guide cut more tibia than it should have.The surgery was completed with a s+n back-up device without delay.The patient current health status is unknown.
|
| |
|
Additional Manufacturer Narrative
|
|
B5: updated.
|
| |
|
Additional Manufacturer Narrative
|
|
H3, h6: given the nature of the alleged incident, the device could not be returned for evaluation; therefore, a device analysis could not be performed.A review of the production order did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.However, by means of an engineering evaluation, our team found that after evaluation, the tibia resection was planned too aggressively given the patient's lateral tibia plateau wear and small anatomy.Although the full leg deformity measured varus, the wear should have been considered, and the resection should have been reduced.However, this is a patient-specific device individually designed and tailor-made for a specific customer.The dimensional non-conformity observed is therefore isolated to this single-use product on complaint.No further containment consideration is needed.The engineer responsible for this case has been made aware of the error.A review of complaint history for the part number over the past 12 months and for the batch number based on historical data of the device did not reveal similar events for the listed device.A review of the instructions for use documents for visionaire¿ patient matched instrumentation revealed that if the patient matched cutting block does not perform as intended, use the standard smith & nephew instrumentation to complete the surgery.A review of the risk management file revealed this failure mode was previously identified.The anticipated risk level is still adequate.A historical review concluded that there are no prior actions related to this product and event.According to inspection drawings, size, implant type, recut type and sawblade thickness shall be verified.Also, part configuration shall be compared to print.At this time, we do have evidence to conclude that the product failed to meet any specifications at the time of manufacture.Since this failure mode rate is within the anticipated acceptable risk limit, the need for corrective action is not indicated.Should additional information be received, the complaint will be reopened.No further investigation is warranted for this complaint; however, we will continue to monitor for future complaints and investigate as necessary.We consider this investigation closed.Additional information: d4 (catalog number, lot number, expiration date, unique identifier (udi) #), h4.Corrected data: d1, h6 (medical device problem code).
|
| |
|