Catalog Number 48004010S
Medical Device Problem Code Burst Container or Vessel (1074)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/12/2024
Type of Reportable Event Malfunction
Event or Problem Description
As reported, when inflating the balloon of a 4mm x 10cm saber percutaneous transluminal angioplasty (pta) balloon catheter, the pressure could not be raised to 6 atmospheres (atm) and a rupture was suspected.The balloon was deflated, but some blood had withdrawn, and the rupture was confirmed.A non-cordis balloon catheter was used as a replacement to complete the procedure.There were no reported injuries to the patient.This was during an arteriovenous (av) shunt pta procedure.The target site vessel characteristics included moderate calcification, severe tortuosity, and 70% stenosis.The device was stored and prepped per the instructions for use (ifu).There was no difficulty removing the stylet or any of the sterile packaging components.The device maintained negative pressure during preparation.A non-cordis 5f sheath was used.The device will not be returned for evaluation.
 
Additional Manufacturer Narrative
Complaint conclusion: as reported, when inflating the balloon of a 4mm x 10cm saber percutaneous transluminal angioplasty (pta) balloon catheter, the pressure could not be raised to 6 atmospheres (atm) and a rupture was suspected.The balloon was deflated, but some blood had withdrawn, and the rupture was confirmed.A non-cordis balloon catheter was used as a replacement to complete the procedure.There were no reported injuries to the patient.This was during an arteriovenous (av) shunt pta procedure.The target site vessel characteristics included moderate calcification, severe tortuosity, and 70% stenosis.The device was stored and prepped per the instructions for use (ifu).There was no difficulty removing the stylet or any of the sterile packaging components.The device maintained negative pressure during preparation.A non-cordis 5f sheath was used.The reported ¿balloon burst - at/below rbp¿ could not be confirmed as the device was not returned for analysis.The exact cause could not be determined.The reported moderate calcification severe tortuosity, and severe stenosis of the fistula may have contributed to the reported event; it is likely to have caused damage to the balloon material that led to its rupture.However, without return of the product for analysis or films of the event it is difficult to draw a clinical conclusion between the device and the reported event.According to the warnings in the safety information in the instructions for use, ¿prior to angioplasty, the catheter should be examined to verify functionality and integrity, and ensure that its size and shape are suitable for the specific procedure for which it is to be used.Do not use if product damage is suspected or evident.To reduce the potential for vessel damage or the risk of dislodgement of particles it is very important that the inflated diameter of the balloon should approximate the diameter of the vessel just proximal and distal to the lesion.The balloon dimensions are printed on the product label.The compliance table incorporated with the product shows how balloon diameter increases as pressure increases.Do not exceed the rated burst pressure recommended on the label.The rated burst pressure is based on the results of in vitro testing.At least 99.9% of the balloons (with a 95% confidence) will not burst at or below their rated burst pressure.Use of a pressure monitoring device is recommended to prevent over-pressurization.Pressure in excess of the rated burst pressure can cause balloon rupture and potential inability to withdraw the catheter through the introducer sheath.Balloon rupture can cause vessel damage and the need for additional intervention.Use only the recommended balloon inflation medium (a 50/50 mixture by volume of contrast medium and normal saline).Never use air or any gaseous medium to inflate the balloon.¿ the information available does not suggest a design or manufacturing related cause for the reported event.Therefore, no corrective or preventive action will be taken at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SABER
Common Device Name
CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
CORDIS US. CORP
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer (Section G)
CORDIS US CORP.
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer Contact
karla castro
coyol free zone, building b25, ,  , costa rica
el coyol alajuela bld 25 CR 2 -01 0
CS   CR 2 01 02
7863138372
MDR Report Key20821105
Report Number3007635982-2024-00278
Device Sequence Number8716986
Product Code LIT
UDI-Device Identifier20705032069783
UDI-Public(01)20705032069783(17)261130(10)82298407
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K971010
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 12/02/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue Number48004010S
Device Lot Number82298407
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/12/2024
Initial Report FDA Received Date12/02/2024
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured12/04/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
5F TERUMO SHEATH.; NON-CORDIS BALLOON CATHETER.
Patient SexUnknown
-
-