| Model Number |
APB-4-10-HX-SS |
| Medical Device Problem Code |
Separation Failure (2547)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
11/25/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Event or Problem Description
|
|
It was reported that during a procedure to treat an unruptured, saccular aneurysm located at the left m1, there was a device-related issue involving the non-detachment of the axium prime bare hx coil.The aneurysm had a maximum diameter of 5 millimeters and a neck diameter of 2 millimeters, with normal blood flow and moderate vessel tortuosity.The coil was fully inserted, but detachment was not achieved.The physician attempted to detach the coil using the instant detacher twice and also made two manual attempts via hypotube.Despite these efforts, the detachment was unsuccessful, and the procedure was completed using a different coil.The patient outcome was reported as alive with no injury.
|
| |
|
Additional Manufacturer Narrative
|
|
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Event or Problem Description
|
|
Additional information was received that the cause of the non-detachment was unknown.Prior to non-detachment, there were no issues encountered.There was no pushwire damage observed after removal from the patient.
|
| |
|