• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SMITHS MEDICAL ASD, INC. BIVONA ADULT TIGHT TO SHAFT SILICONE TRACHEOSTOMY TUBE, CUFFED; TUBE TRACHEOSTOMY AND TUBE CUFF

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SMITHS MEDICAL ASD, INC. BIVONA ADULT TIGHT TO SHAFT SILICONE TRACHEOSTOMY TUBE, CUFFED; TUBE TRACHEOSTOMY AND TUBE CUFF Back to Search Results
Catalog Number 670170
Medical Device Problem Code Inflation Problem (1310)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/01/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
B3.Date of event: unknown.No information has been provided to date.Reason device not evaluated by mfg: other; device was not returned to manufacturer.Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.
 
Event or Problem Description
It was reported that the cuff was defective and did not completely encircle the tube/stuck to one side of the tube.The issue was discovered prior to patient use.The event occurred during testing of the cuff.There was no harm/adverse event reported.
 
Additional Manufacturer Narrative
D9.Date returned to mfg: 27-nov-2024.H6.Investigation codes: updated.Investigation summary: received one (1) new list# 670170 tts tracheostomy tube.As received no damage or anomalies were observed.A syringe was attached to the pilot balloon of the tube and slowly inflated with 10ml of sterile water per packaging directions.The cuff of the set was observed to inflate completely as normal.The complaint of cuff not fully encircling the tube cannot be replicated or confirmed, and no root cause could be determined.A review of the device history record (dhr) shows there were no observations or nonconformities recorded during manufacture to suggest an issue of this nature would occur with this lot of products.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BIVONA ADULT TIGHT TO SHAFT SILICONE TRACHEOSTOMY TUBE, CUFFED
Common Device Name
TUBE TRACHEOSTOMY AND TUBE CUFF
Manufacturer (Section D)
SMITHS MEDICAL ASD, INC.
5700 w 23rd ave
gary IN 46406
Manufacturer Contact
reed covert
6000 nathan ln n
minneapolis, MN 55442
2247062300
MDR Report Key20833243
Report Number1824231-2024-00100
Device Sequence Number8730336
Product Code JOH
UDI-Device Identifier15021312006056
UDI-Public(01)15021312006056(17)270523(10)4291369
Combination Product (Y/N)N
Initial Reporter StateCO
Initial Reporter CountryUS
PMA/510(K) Number
UNKNOWN
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Distributor
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/07/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number670170
Device Lot Number4291369
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/13/2024
Supplement Date Received by Manufacturer02/10/2025
Initial Report FDA Received Date12/03/2024
Supplement Report FDA Received Date03/07/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/28/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-