| Model Number |
VICM512.1 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Toxic Anterior Segment Syndrome (TASS) (4469)
|
| Date of Event |
04/13/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
A4-a6: unk.H6: work order search: no similar complaints within associated lots were found.Manufacturer narrative: a review of the device labeling was completed.Iritis (iridocyclitis), anterior chamber cells and fibrin precipitation are identified in the labeling as known potential adverse events following icl implantation.The dfu states precautions to physicians (10) this product should not be immersed in anything other than commonly used intraocular irrigation fluids or viscoelastic substances.Precaution (6) after inserting this product, aspirate the viscoelastic substance completely from inside the eye.Do not use highly viscous viscoelastic substances that are difficult to aspirate completely.(b)(6) were used during the procedure and is a viscous cohesive of purified sodium hyaluronate manufactured by seikagaku.(11) when folding and inserting this product, use the following insertion device.Microstaar injector, microstaar foam tip plunger, icl cartridge.To avoid damaging the product, use forceps with rounded edges and no serrations on the surface.Toxic anterior segment syndrome (tass) is an acute sterile postoperative inflammation that can occur after uncomplicated or complicated intraocular surgery.The handpiece (which is a reusable instrument) was used.While improper sterilization and contamination of surgical instruments remains the most common risk factor associated with tass, ocular viscoelastic, and improper preparation of antibiotics for intracameral injection may also lead to tass.It should be noted multiple cases of similar clinical presentation were reported from the same facility under the same surgeon.An exact cause could not be determined as the event could be multifactorial in nature including patient and/or procedure related factors.Claim# (b)(4).
|
| |
|
Event or Problem Description
|
|
The reporter indicated that the surgeon implanted an implantable collamer lens into a right eye (od) on (b)(6)2024.The patient underwent bilateral sequential surgery.Concomitant products used intraoperatively include the msi-pf injector, sfc-45 cartridge with foam tip plunger, ovd (b)(6) and coaxial i/a handpiece for its removal for 60 sec.Tass was diagnosed on day 1.Inflammation was reported as moderate presenting with ac cell+++, ciliary hyperemia and mild fibrin over the pupil resulting in patient experience of blurred vision.Treatment included: ac lavage, topical, oral and subconjunctival injection of steroids.The issue was resolved on day 2 and the lens remains implanted.Per information on (b)(6)2024, ocular status was reported as ucva 20/13 and iop 11mmhg.The reporter does not state a cause for the event.
|
| |
|
Additional Manufacturer Narrative
|
|
H6: device history record review indicates that the product has been manufactured within the established process parameters and that there is no indication that the manufacturing and/or processing of the device contributed to the complaint issue.(b)(4).
|
| |
|
Search Alerts/Recalls
|