Model Number 102812-81A
Medical Device Problem Code Failure to Sense (1559)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/04/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The manufacturer is currently performing an investigation and will provide the results with the supplemental report.
 
Event or Problem Description
On november 4, 2024, senseonics was made aware of an incident where user received an early sensor replacement alert resulting in an early sensor removal.
 
Additional Manufacturer Narrative
The sensor replacement alert was first presented to the user on (b)(6) 2024, day 21 after insertion.The sensor was tested in-house, but the failure mode could not be reproduced during the return product analysis testing.This may occur in some instances where the failure mode that presents itself is in the body is not reproduced in the lab.The review of the sensor data in dms showed the sensor was taking longer than usual to stabilize after insertion, which eventually triggered the sensor replacement alert.The potential root cause for this slow recovery post-insertion is coagulated blood from the insertion process interfering with the interface of the hydrogel.As part of resolution, the rma was authorized for sensor replacement.B4.Date of this report 31 january 2025.G3.Date received by the manufacturer? 31 january 2025.H3.Device evaluated by manufacturer? yes.H6.Type of investigation updated to 10.H6.Investigation findings updated to 114.H6.Investigation conclusions updated to 4315.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVERSENSE SENSOR
Common Device Name
EVERSENSE CONTINUOUS GLUCOSE MONITOR SYSTEM
Manufacturer (Section D)
SENSEONICS INC.
20451 seneca meadows parkway
germantown MD 20876 7005
Manufacturer (Section G)
SENSEONICS INC.
20451 seneca meadows parkway
germantown MD 20876 7005
Manufacturer Contact
vallikannu somasundaram
20451 seneca meadows parkway
germantown, MD 20876-7005
MDR Report Key20845999
Report Number3009862700-2024-01090
Device Sequence Number20871080
Product Code QHJ
UDI-Device Identifier00817491022974
UDI-Public00817491022974
Combination Product (Y/N)Y
Initial Reporter CountryUS
PMA/510(K) Number
P160048
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2024
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 01/31/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date05/02/2025
Device Model Number102812-81A
Device Catalogue NumberFG-7202-00-301
Device Lot NumberWP09978
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/27/2024
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/04/2024
Supplement Date Received by Manufacturer01/31/2025
Initial Report FDA Received Date12/04/2024
Supplement Report FDA Received Date01/31/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/12/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age68 YR
Patient SexFemale
-
-