Product complaint # (b)(4).H6 component code: g07002 - no device problem found.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.A manufacturing record evaluation was performed for the finished device lot, and no non-conformances were identified.Additional information was requested, and the following was obtained via: lot number? ubmhqq provide the source or name and title of external person providing answers to follow-up (external person submitting answers to sales rep or loc/bq).(b)(4) please perform and document the follow up attempt for product return.Please document the shipment tracking number in notes or rmao sections.=the device has been received at sukagawa and will be shipped.Please check rmao.Tracking number: (b)(4).H3 investigation summary: the product was returned to ethicon for evaluation.Fifteen unopened samples were received for analysis.Product code jb946, lot ubmhqq.As per the sampling plan, a visual inspection was performed on thirteen samples, the packets were opened, and the swage and attachment area was noted as expected.The sutures were dispensed without problems and examined along the strand no anomalies were observed during evaluation.The functional test was performed using instron equipment and the pull force result was above the minimum requirements.As part of the ethicon quality process, all devices are manufactured, inspected, and released to approved specifications.The event described could not be confirmed as the device performed without any difficulties noted.Although no product defect was identified, there may have been other circumstances or issues that occurred during the use of the device that could not be replicated during the laboratory analysis.H3 investigation summary: the product was returned to ethicon for evaluation.One needle and one suture were received for analysis.Product code jb946h.During the visual inspection of needle, the swage and attachment area were noted as expected.The barrel hole was examined under magnification and remnant suture was noted.The suture end is severely cut, resulting in a clip off defect.Based on the information currently available, clip off was identified during the investigation of the sample received.This product issue will be addressed through the ethicon quality system.Additional complaint information monitoring for potential safety signals will be conducted through complaint trending as part of post-market surveillance.
|
|
Product complaint # (b)(4).Date sent to the fda: 1/2/2025.Corrected information: h6 (investigational codes submitted in the initial report).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|