EXACTECH, INC. ONE PEG PATELLA 32MM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Model Number |
ONE PEG PATELLA 32MM |
| Medical Device Problem Codes |
Unstable (1667); Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Failure of Implant (1924); Pain (1994); Synovitis (2094); Joint Laxity (4526); Joint effusion (4849)
|
| Date of Event |
01/24/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Legal case-usa.As reported via legal documentation the patient had a right knee replacement on (b)(6) 2013.Approximately 9 years and 6 months after the initial procedure the patient had a right knee revision on (b)(6) 2023.There is no other patient demographic or medical history available.There is no device return.There are no photos or other images of the device provided.No additional information is available.Revision op report on (b)(6) 2023 diagnosis: failed right patella implant and polyethylene insert polyethylene insert was removed which showed excessive wear.The patella everted, showed extensive wear.The patient was brought to recovery room in stable condition.Ebi initial surgery attached.Historical record & smartsolve searched for sn/patient name with no results.Operative report from revision surgery attached.As directed by qa management: this legal complaint for polyethylene issues occurred in the us.The event did not occur in, nor is it reportable for australia, brazil, canada, eea/eu, japan, taiwan, or great britain, excluding northern ireland.Therefore, only the us reportability determination will be assessed.
|
| |
|
Additional Manufacturer Narrative
|
|
The device was not returned for evaluation and no medical or other records containing treatment information or patient information have been received; therefore, the reported event cannot be confirmed, nor can the circumstances or potential causes or contributors to the alleged event be evaluated.Should additional, material information become available that permits more analysis or conclusions, a supplemental report will be filed accordingly.D10: concomitants: (b)(6), 02-012-47-3011 - logic cr tib insert std, sz 3, 11mm.(b)(6), 02-012-45-3030 - lgc tibial fit tray cem sz 3f / 3t.(b)(6), 02-010-03-0330 - logic cr femoral cem, right, sz 3.(b)(6), 201-78-25 - small headed sharp pin, 1 1/8" 4 pack.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay corrected information.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|
Event or Problem Description
|
|
As reported via legal documentation the patient had a right knee replacement on (b)(6) 2013.Approximately 9 years and 6 months after the initial procedure the patient had a right knee revision on (b)(6) 2023.There is no other patient demographic or medical history available.There is no device return.There are no photos or other images of the device provided.No additional information is available.
|
| |
|