| Model Number |
ZEPHYR 4.0 EBV |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Fistula (1862); Pneumothorax (2012)
|
| Date of Event |
10/22/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Pneumothorax is the most common side effect associated with the zephyr valve treatment (criner et al.A multicenter randomized controlled trial of zephyr endobronchial valve treatment in heterogeneous emphysema (liberate).Am j respir crit care med.2018; 198 (9): 1151-1164).Targeted lobar deflation likely causes inflation of the ipsilateral lobe, which can result in a tear of the already compromised parenchymal tissue of the emphysematous ipsilateral lobe, resulting in a pneumothorax (criner et al.A multicenter randomized controlled trial of zephyr endobronchial valve treatment in heterogeneous emphysema (liberate).Am j respir crit care med.2018; 198 (9): 1151-1164).In the liberate study (ide clinical study used to support pma p180002's approval), 26.6% of the zephyr valve subjects experienced a pneumothorax in the treatment period ([less than or equal to 45 days).These were managed using standard of care procedures as per previously published guidelines (valipour, arschang, et al.Respiration 87.6 (2014): 513-521).In 17.4% of the events, the pneumothorax resolved without any additional intervention with subjects under careful observation.In over half the events (56.5%), the pneumothorax was managed with a chest-tube only.An additional 13% of the events were managed with a chest-tube and the temporary removal of one or more valves, while another 13% of the events were managed with a chest-tube and removal of all the implanted valves.Upon successful resolution of the pneumothorax, removed valves can be replaced.Patients that experienced a pneumothorax experienced clinical benefits of the zephyr valve treatment that were similar to the benefits experienced by patients who did not have a pneumothorax.The zephyr ebv system ifu and pulmonx training program both specifically reference pneumothorax as a known side effect of this procedure and the published guidelines (valipour, arschang, et al."expert statement: pneumothorax associated with endoscopic valve therapy for emphysema-potential mechanisms, treatment algorithm, and case examples." respiration 87.6 (2014): 513-521).The reported event aligns with the experience observed in the liberate clinical study and is an expected side effect to the zephyr valve treatment.
|
| |
|
Event or Problem Description
|
|
The patient underwent blvr on (b)(6) 2024 with implantation of 5 valves in the right upper and right middle lobes.On (b)(6) 2024, the patient experienced a pneumothorax, and a chest tube was placed.On (b)(6) 2024, the chest tube was placed on a water seal.On (b)(6) 2024, the patient underwent a thoracoscopy and pleurodesis was performed in addition to a right middle lobe blebectomy to address the alveolar pleural fistula.The patient was transferred to the icu.On (b)(6) 2024, the patient tested positive for mrsa pneumonia and put on iv antibiotics.On (b)(6)2024, one valve was explanted.On (b)(6)2024, a second chest tube was inserted.On (b)(6)2024, the remaining valves were explanted.On (b)(6)2024, a single valve was implanted to address the ongoing air leak.The patient was discharged to long-term care on (b)(6)2024, with the pneumothorax ongoing.Further information will be reported once available.
|
| |
|
Event or Problem Description
|
|
The patient underwent blvr on (b)(6) 2024 with implantation of 5 valves in the right upper and right middle lobes.On (b)(6) 2024, the patient experienced a pneumothorax, and a chest tube was placed.On (b)(6) 2024, the chest tube was placed on a water seal.On (b)(6) 2024, the patient underwent a thoracoscopy and pleurodesis was performed in addition to a right middle lobeblebectomy to address the alveolar pleural fistula.The patient was transferred to the icu.On (b)(6) 2024, the patient tested positive for mrsa pneumonia and put on iv antibiotics.On (b)(6) 2024, one valve was explanted.On (b)(6) 2024, a second chest tube was inserted.On (b)(6) 2024, the remaining valves were explanted.On (b)(6) 2024, a single valve was implanted to address the ongoing air leak.The patient was discharged to long-term care on (b)(6) 2024, with the pneumothorax ongoing.The patient had chest tubes removed and was discharged (b)(6) 2025.
|
| |
|
Search Alerts/Recalls
|
|