|
EXACTECH, INC. TRAPEZOID TIBIAL TRAY SZ 3F/3T; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
204-04-33 |
| Medical Device Problem Codes |
Naturally Worn (2988); Loosening of Implant Not Related to Bone-Ingrowth (4002)
|
| Health Effect - Clinical Codes |
Pain (1994); Synovitis (2094); Discomfort (2330); Osteolysis (2377); Ambulation or Postural Difficulties (2544); Balance Problems (4401); Metal Related Pathology (4530); Swelling/ Edema (4577); High metal ion levels (4847)
|
| Date of Event |
07/25/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
1038671-2023-00513.1038671-2024-04710 concomitants: 200-02-35 - three peg patella 35mm.200-63-09 - cr tibial insert sz 3, 9mm, slope +.230-03-03 - optetrak asy, cr cemented femoral, sz 3.Multiple mdr reports were filed for this event, please see associated reports: 1038671-2023-00513 and 1038671-2024-04710.The device will not be returned for analysis; however, an investigation of the reported event is in progress.Once the investigation is completed, a supplemental medwatch 3500a will be submitted.
|
| |
|
Event or Problem Description
|
|
It was reported via legal documentation that approximately 61 months after a right total knee replacement procedure, the patient underwent a revision procedure to address secondary to significant polyethylene liner wear with resulting metallosis, osteolysis, and synovitis, daily knee pain and discomfort which limit activities of daily living and recreation and impacts quality of life.There is no device return.Initial surgery and revision surgery operative notes were provided.Patient left the operating room in stable condition.Post operative diagnosis noted wear and loosening of the implant.No further issues or complications were reported.No additional information is available.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and/or corrected information.The following sections were updated: g3/g4, h6.The following sections were corrected: h4, h6.Mdr section codes updated/corrected: b, c, e, g.The reason for the revision reported cannot be confirmed from the information provided but may be the result of prosthesis wear, femoral loosening, and tibial loosening or due to inclusion of the polyethylene in the packaging recall.Potential contributions of user and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and images and radiographs were not provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|
Search Alerts/Recalls
|
|
|