|
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.D4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.H6 component code: g07002 device not returned.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.The single complaint was reported with multiple events.There are no additional details regarding the additional patient events.Attempts are being made to obtain the information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.- it was reported that "was informed by one of the nurses that the vascular team has been experiencing issues with needles popping off".- please confirm the number of patients affected by this alleged deficiency? - have any of these events been previously reported to ethicon? if so, provide the respective reference number(s).If no, please create a new pc file for each patient/event.Please provide information requested below for each patient/event.- what are the procedure name(s) and date(s)? - were there patient consequences? if yes, please specify.- can you identify the lot numbers and product code of the product that was used? - how many devices demonstrated the alleged deficiency on each involved patient event? -what was being done when the needle pulled-off (removal from package / during handling prior to use on patient/ during passage through tissue / during tying / post-op)? -did the needle fall into the patient? if so, please provide the following information: -were x-rays taken to locate the needle? -was the needle piece removed from the patient during the same procedure? c.Does the needle remain in the patient¿s tissue? d."what tissue structure is it located? size of the needle retained e.Are any plans in place to remove the needle piece in future?" -if retained, what is the surgeon's opinion of consequences to the patient?.
|