| Catalog Number |
74027241 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Damage to Ligament(s) (1952); Joint Laxity (4526); Insufficient Information (4580)
|
| Date of Event |
11/12/2019
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Internal complaint reference: (b)(4).This complaint was opened by smith+nephew to document a patient complication reported that includes reference to the use of a smith+nephew product without evidence about a specific product problem.The reported complication relates to known inherent procedural risks that are appropriately documented in our risk files.Smith+nephew will continue to monitor trends in accordance with our post-market surveillance process and take necessary action as required if anticipated severity and/or occurrence rates are exceeded.Smith+nephew has no reason to suspect that the product failed to meet any specifications at the time of manufacture.Based on our review of all currently available information, we are unable to confirm a relationship between the reported event and the device or identify a definitive root cause.However, as the use of our product cannot be excluded as a potential cause or contributory factor to the reported issue, we are submitting this report in accordance with applicable regulations.If additional investigative findings or information becomes available that alters the conclusions of this report, a follow-up report will be submitted as required.
|
| |
|
Event or Problem Description
|
|
It was reported that, after a tka surgery had been performed on (b)(6) 2018 and a patellar implantation performed on (b)(6) 2019, a revision surgery was performed on (b)(6) 2020 due to unknown reasons.During this surgery the insert jrny ii bcs xlpe art isrt sz 3-4 lt 9mm and patellar component gns ii biconvex pat 26mm were exchanged.Current health status of the patient is unknown.
|
| |
|
Event or Problem Description
|
|
It was reported that, after a tkr surgery that had been performed on (b)(6) 2018, a revision surgery was performed on (b)(6) 2019 due to loose ligaments.During this surgery the patellar component and the insert were exchanged.The jrny ii bcs xlpe art isrt sz 3-4 lt 9mm was exchanged to a 12mm insert (jrny ii bcs xlpe art isrt sz 3-4 lt 12mm).Current health status of the patient is unknown.
|
| |
|
Additional Manufacturer Narrative
|
|
H2: additional information ¿b5, h6¿.
|
| |
|
Additional Manufacturer Narrative
|
|
Corrected data: b3 (occurrence date), d6a, d6b, h6 (health effect - clinical code, type of investigation).Updated results of investigation: the devices were not returned for evaluation; therefore, a device analysis could not be performed.A review of the production orders did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.A review of complaint history for the part numbers over the past 12 months and for the batch numbers based on historical data of the device did not reveal similar events for the listed devices.A review of the instructions for use documents for knee systems provides complete guidelines of indications, contraindications, warnings and precautions and possible adverse effects that may occur preoperative, during surgery or post operative.A review of the risk management files revealed this failure mode was previously identified.The anticipated risk level is still adequate.A historical review concluded that there are no prior actions related to these products and event.At this time, we have no evidence to conclude that the products failed to meet any specifications at the time of manufacture.Factors that could contribute to the reported event include post-operative healing issue and/or patient condition.Based on this investigation, the need for corrective action is not indicated.Should the devices or additional information be received, the complaint will be reopened.No further investigation is warranted for this complaint; however, we will continue to monitor for future complaints and investigate as necessary.We consider this investigation closed.
|
| |
|