EXACTECH, INC. LOGIC TIBIA IMPLANT PSC INSERT, SZ 1.5, 11MM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
02-012-44-1511 |
| Medical Device Problem Code |
Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Pain (1994); Synovitis (2094); Ambulation or Postural Difficulties (2544)
|
| Date of Event |
03/14/2016
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
As reported via legal documentation the patient had a left knee replacement on (b)(6) 2013.Approximately 3 years and 2 months after the initial procedure the patient had a left knee revision on (b)(6) 2016.The patient has suffered the following injuries and complications: pain, difficulty with everyday activities, trouble walking.There is no other patient demographic or medical history available.There is no information on the surgical procedure or patient outcome.There is no device return.There are no photos or other images of the device provided.No additional information is available.Postoperative diagnosis: failed left total knee arthroplasty secondary to aseptic femoral and tibial loosening.Procedure: there is significant hypertrophic inflammatory synovitis a complete synovectomy was performed.On inspection of the components of the patella, component was well fixed.The femoral and tibial components were grossly loose they were extracted there is necrotic bone beneath the components.Residual cement and fibrinous debris was removed.Devices were trailed and then the implants seated.All were assessed and found to be satisfactory.The patient was awakened and transferred to the recovery room.Patient was revised to exactech devices.
|
| |
|
Additional Manufacturer Narrative
|
|
Report number: 1038671-2023-01970 d10 concomitants: tray tib (02-012-45-1515, (b)(6), patella 3 peg (200-02-29, (b)(6), logic femoral ps cem left sz 1.5 (02-010-01-0215, (b)(6).The product associated with the reported event is within the scope of recall z-0021-2022; however, there is insufficient information to evaluate whether the subject issue of the recall was a cause or contributor to the reported event.Multiple mdr reports were filed for this event, please see associated reports: 1038671-2023-01970.The reason for the revision reported cannot be confirmed from the information provided but may be the result of prosthesis wear, femoral loosening, and tibial loosening or due to inclusion of the polyethylene in the packaging recall.Potential contributions of user and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and images and radiographs were not provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|
Additional Manufacturer Narrative
|
|
Report number: 1038671-2023-01970, 1038671-2025-00038.This follow-up report is being submitted to relay additional and/or corrected information.The reason for the revision reported cannot be confirmed from the information provided but may be the result of prosthesis wear, femoral loosening, and tibial loosening or due to inclusion of the polyethylene in the packaging recall.Potential contributions of user and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and images and radiographs were not provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|
Event or Problem Description
|
|
As reported via legal documentation the patient had a left knee replacement on (b)(6) 2013.Approximately 3 years and 2 months after the initial procedure the patient had a left knee revision on (b)(6) 2016.The patient has suffered the following injuries and complications: pain, difficulty with everyday activities, trouble walking.There is no other patient demographic or medical history available.There is no device return.There are no photos or other images of the device provided.No additional information is available.Postoperative diagnosis: failed left total knee arthroplasty secondary to aseptic femoral and tibial loosening.Procedure: there is significant hypertrophic inflammatory synovitis a complete synovectomy was performed.On inspection of the components of the patella, component was well fixed.The femoral and tibial components were grossly loose they were extracted there is necrotic bone beneath the components.Residual cement and fibrinous debris was removed.Devices were trialed and then the implants seated.All were assessed and found to be satisfactory.The patient was awakened and transferred to the recovery room.Patient was revised to exactech devices.
|
| |
|