C.R. BARD, INC. (BASD) -3006260740 PowerPort Slim Implantable Port, ChronoFlex Single-Lumen, 6F; Port & Catheter, Implanted, Subcutaneous, Intravascular
|
Back to Search Results |
|
| Catalog Number |
1716001 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Bacterial Infection (1735); Erythema (1840); Unspecified Infection (1930); Pain (1994)
|
| Date of Event |
11/09/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
H10: as the lot number for the device was provided, a review of the device history records will be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.H11: section a through f ¿ the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported through litigation process that about sometime later post port placement procedure, the patient allegedly developed with infection.However, the current status of the patient was unknown.
|
| |
|
Event or Problem Description
|
|
It was reported through litigation process that on (b)(6) 2021, the patient underwent the port placement procedure via left internal jugular vein for poor venous access.Approximately one year and twenty four days later, on (b)(6) 2023, patient developed with pain and redness around the port site.Subsequently, the port was removed on (b)(6) 2023.Further, approximately two days later, on (b)(6) 2023, patient was diagnosed with acinetobacter baumannii bacterial infection.Additionally, patient was diagnosed with an unspecified infection.However, the current status of the patient remains unknown.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: manufacturing review: a manufacturing review was not required as this is the only complaint reported to date for this product and lot.Investigation summary: although the physical device was not returned for evaluation, medical records were provided for review.Medical record alleges that, the patient underwent an implantable port placement procedure via left internal jugular vein using powerport for poor venous access.A final fluoro run was used to verify final catheter placement at the cavoatrial junction.Approximately, one year and twenty four days later, the patient presented with pain and redness around the port site.Next day, the patient was planned for port removal.Then two days later, the patient was diagnosed with acinetobacter baumannii.Therefore, it can be confirmed that the patient had experienced pain and redness around the port site and also the patient was diagnosed with acinetobacter baumannii.However, the relationship to the port is unknown.A review of sterilization records, endotoxin testing results, and bioburden data was conducted in accordance with applicable quality system and regulatory requirements, and no nonconformances or anomalies were identified.Based upon the available information, the definitive root cause is unknown.Labeling review: as the reported event did not allege a labeling or use related issue, a labeling review is not required.B3, b5, d1, g3, h6 (patient, method, result).Section a through f: the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|