• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. ECLIPSE TRUNION 45MM, SLOTTED, TPS CAP; TOT ANAT SHOULDR PROSTH, UNCEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. ECLIPSE TRUNION 45MM, SLOTTED, TPS CAP; TOT ANAT SHOULDR PROSTH, UNCEM Back to Search Results
Model Number ECLIPSE TRUNION 45MM, SLOTTED, TPS CAP
Medical Device Problem Code Positioning Failure (1158)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 12/16/2024
Type of Reportable Event Malfunction
Event or Problem Description
On 12/16/2024, it was reported by a sales representative via email that an ar-9400-sbk eclipse speedscap implant system did not get sufficient fixation with the eclipse trunion and cage screw.The case was completed using a long stem.This was discovered during an anatomic total shoulder procedure on (b)(6) 2024.Additional information received on 12/30/2024: the part numbers ar-9301-02 and cage screw and ar-9301-45cpc arthrex eclipse trunion were provided.Additionally, the sales representative reported that another ar-9400-sbk eclipse speedscap implant system from a different lot number and an ar-9301-01 arthrex eclipse cage screw was attempted to be used as well but still could not get sufficient fixation.The case was completed using an ar-9100-05m univers apex optifit humeral stem.The case was delayed between thirty to forty minutes; however, additional anesthesia was not needed.
 
Additional Manufacturer Narrative
Investigation is in process.A follow-up report will be provided upon availability of additional information.
 
Additional Manufacturer Narrative
Additional information: g3, h3, h6 based on the information provided which may include the device (if available and returned), pictures, videos, event description, and any additional information from the field, arthrex was able to conclude a most likely cause.The most likely cause for the reported failure can be attributed to user error due to misaligned insertion and/or improper bone preparation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ECLIPSE TRUNION 45MM, SLOTTED, TPS CAP
Common Device Name
TOT ANAT SHOULDR PROSTH, UNCEM
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key21136741
Report Number1220246-2025-09365
Device Sequence Number6957538
Product Code QHQ
UDI-Device Identifier00888867276154
UDI-Public00888867276154
Combination Product (Y/N)N
Initial Reporter StateMD
Initial Reporter CountryUS
PMA/510(K) Number
K183194
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Distributor
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 07/08/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberECLIPSE TRUNION 45MM, SLOTTED, TPS CAP
Device Catalogue NumberAR-9301-45CPC
Device Lot Number23.04567
Was Device Available for Evaluation? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/16/2024
Supplement Date Received by Manufacturer06/13/2025
Initial Report FDA Received Date01/13/2025
Supplement Report FDA Received Date07/08/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-